               Table 2. Sensing technologies for muscle health monitoring
                                                                        Response  Detection  Limit of  Technological           Current
               Sensor type  Target signal  Detection principle  Sensitivity                                     Main advantages             Comfort References
                                                                        time     range    detection  maturity                  limitations
                                                                                                                               Electrode
                                                                                                                Real-time analysis;  placement
               Bioelectrical  sEMG        Bioelectrical signal  NA      NA       NA       NA       High         High temporal  sensitivity;  Medium  [74]
               sensors                    acquisition                                                           resolution;    Motion artifacts;
                                                                                                                Non-invasiveness
                                                                                                                               Cross-talk
                          Energy                                                                                Real-time analysis;  Low integration;
                          metabolism  Lactic  Enzyme-based   ~ 644.2    1 min    0-30 mM  1 mM     Medium       Non-invasiveness;  Lab validation  High  [75]
                          biomarkers  acid  electrochemical sensing  nA/mM                                      Ease to use    only
                                                                                                                Real-time analysis;  Fabrication
                                          Colorimetry        ~ 12.3 /decade  NA  0-100 mM  1.5 mM  High                                     High   [76]
                                                                                                                Ease to use    complexity
                                          Enzyme-based       ~ 60                                                              Lab validation
                                    Urea                                5 min    0-200 mM  5 mM    Low          Ease to use                 Medium  [77]
                                          electrochemical sensing  mV/decade                                                   only
                                                                                                                               Lab validation
                                          Colorimetry        ~ 30 /decade  4 min  0-30 mM  5 mM    Low          Multiplex detection         Medium  [78]
                                                                                                                               only
                                                                                                                               Specialized
               Biochemical  Muscle injury  Mb  Immunochromatography  ~ 0.001  5 min  0-1000  0.05 ng/mL  Low    Multiplex detection;  equipment  Low  [79]
               sensors    biomarkers                         /(ng/mL)            ng/mL                          High sensitivity  dependence; Lab
                                                                                                                               validation only
                                                                                                                               Architecture
                                                             ~ 0.023             0-1 × 10 4                     Self-powered;
                                          Electrochemical transduction  1 min             0.011 ng/mL Low                      complexity; Lab  Low  [80]
                                                             V/decade            ng/mL                          Ultra-sensitivity
                                                                                                                               validation only
                                                                                                                               Specialized
                                                             ~ 0.014             0-250    0.063                 Multiplex detection;  equipment
                                    CK    Immunochromatography          5 min                      Medium                                   Low    [79]
                                                             /(ng/mL)            ng/mL    ng/mL                 High sensitivity  dependence; Lab
                                                                                                                               validation only
                                                                                                                               Cascade reaction
                                          Enzyme -based                                                                        dependent;
                                          electrochemical glucose  ~ 0.0147  5 min  0-0.5 U/mL  0.00147  Low    Label-free; Ease to use  Indirect  NA  [81]
                                          sensing            /(U/mL)                      U/mL                                 detection; Lab
                                                                                                                               validation only
                          Inflammatory    Aptamer-based      ~ 0.62                                             Multiplex detection;  Fabrication
                          biomarkers  IL-6  electrochemical sensor  /(ng/mL)  1 min  0-30 ng/mL  1.3 ng/mL  Medium  Clinical validation  complexity  Medium  [82]
                                                                                                                               Narrow range;
                                                             ~ 0.006                                            Label-free; Simple
                                          Colorimetry                   5 min    0-125 μg/mL 1.95 μg/mL  Low                   Lab validation  NA  [83]
                                                             /(μg/mL)                                           readout
                                                                                                                               only
                                          Aptamer-based      ~ 0.12                                             Multiplex detection;  Fabrication
                                    TGF-β                               1 min    0-150 pg/mL 6.0 pg/mL  Medium                              Medium  [82]
                                          electrochemical sensor  /(pg/mL)                                      Clinical validation  complexity