Chang et al. Soft Sci. 2026, 6, 29                           Page 9 of 26





 Table 2. Sensing technologies for muscle health monitoring
 Response  Detection  Limit of  Technological  Current
 Sensor type  Target signal  Detection principle  Sensitivity  Main advantages  Comfort References
 time  range  detection  maturity          limitations
                                           Electrode
                           Real-time analysis;  placement
 Bioelectrical  sEMG  Bioelectrical signal  NA  NA  NA  NA  High  High temporal  sensitivity;  Medium  [74]
 sensors  acquisition      resolution;     Motion artifacts;
                           Non-invasiveness
                                           Cross-talk
 Energy                    Real-time analysis;  Low integration;
 metabolism  Lactic  Enzyme-based  ~ 644.2  1 min  0-30 mM  1 mM  Medium  Non-invasiveness;  Lab validation  High  [75]
 biomarkers  acid  electrochemical sensing  nA/mM  Ease to use  only
                           Real-time analysis;  Fabrication
 Colorimetry  ~ 12.3 /decade  NA  0-100 mM  1.5 mM  High  High  [76]
                           Ease to use     complexity
 Enzyme-based  ~ 60                        Lab validation
 Urea  5 min  0-200 mM  5 mM  Low  Ease to use          Medium  [77]
 electrochemical sensing  mV/decade        only
                                           Lab validation
 Colorimetry  ~ 30 /decade  4 min  0-30 mM  5 mM  Low  Multiplex detection  Medium  [78]
                                           only
                                           Specialized
 Biochemical  Muscle injury  Mb  Immunochromatography  ~ 0.001  5 min  0-1000  0.05 ng/mL  Low  Multiplex detection;  equipment  Low  [79]
 sensors  biomarkers  /(ng/mL)  ng/mL  High sensitivity  dependence; Lab
                                           validation only
                                           Architecture
 ~ 0.023  0-1 × 10 4       Self-powered;
 Electrochemical transduction  1 min  0.011 ng/mL Low  complexity; Lab  Low  [80]
 V/decade  ng/mL           Ultra-sensitivity
                                           validation only
                                           Specialized
 ~ 0.014  0-250  0.063     Multiplex detection;  equipment
 CK  Immunochromatography  5 min  Medium                Low    [79]
 /(ng/mL)  ng/mL  ng/mL    High sensitivity  dependence; Lab
                                           validation only
                                           Cascade reaction
 Enzyme -based                             dependent;
 electrochemical glucose  ~ 0.0147  5 min  0-0.5 U/mL  0.00147  Low  Label-free; Ease to use  Indirect  NA  [81]
 sensing  /(U/mL)  U/mL                    detection; Lab
                                           validation only
 Inflammatory  Aptamer-based  ~ 0.62  Multiplex detection;  Fabrication
 biomarkers  IL-6  electrochemical sensor  /(ng/mL)  1 min  0-30 ng/mL  1.3 ng/mL  Medium  Clinical validation  complexity  Medium  [82]
                                           Narrow range;
 ~ 0.006                   Label-free; Simple
 Colorimetry  5 min  0-125 μg/mL 1.95 μg/mL  Low  Lab validation  NA  [83]
 /(μg/mL)                  readout
                                           only
 Aptamer-based  ~ 0.12     Multiplex detection;  Fabrication
 TGF-β  1 min  0-150 pg/mL 6.0 pg/mL  Medium            Medium  [82]
 electrochemical sensor  /(pg/mL)  Clinical validation  complexity