Page 199 - Read Online
P. 199
Page 8 of 8 Tumscitz et al. Vessel Plus 2019;3:20 I http://dx.doi.org/10.20517/2574-1209.2018.71
and outcome. Circulation,1994;90:2725-30.
8. Javaid A, Buch AN, Satler LF, Kent KM, Suddath WO, et al. Management and outcomes of coronary artery perforation during
percutaneous coronary intervention. Am J Cardiol 2006;98:911-4.
9. Al-Lamee R, Ielasi A, Latib A, Godino C, Ferraro M, et al. Incidence, predictors, management, immediate and long-term outcomes
following grade III coronary perforation. JACC Cardiovasc Interv 2011;4:87-95.
10. Werner GS, Ferrari M, Heinke S, Kuethe F, Surber R, Richartz BM, et al. Angiographic assessment of collateral connections in
comparison with invasively determined collateral function in chronic coronary occlusions. Circulation 2003;107:1972-7.
11. Kilic ID, Fabris E, Serdoz R, Caiazzo G, Foin N, et al. Coronary covered stents. EuroIntervention;12:1288-95.
12. Hadjimiltiades S, Paraskevaides S, Kazinakis G, Louridas G. Coronary vessel perforation during balloon angioplasty: a case report.
Cathet Cardiovasc Diagn 1998;45:417-20.
13. Komatsu I, Hirano K, Takimura H, Araki M, Yamawaki M, et al. A case of coronary artery perforation with successful hemostasis using
over-the-wire balloon and autologous blood perfusion. Cardiovasc Interv Ther 2013;28:197-201.
14. Dixon SR, Webster MW, Ormiston JA, Wattie WJ, Hammett CJ. Gelfoam embolization of a distal coronary artery guidewire perforation.
Catheter Cardiovasc Interv 2000;49:214-7.
15. Sto¨rger H, Ruef J. Closure of guide wire-induced coronary artery perforation with a two-component fibrin glue. Catheter Cardiovasc
Interv 2007;70:237-40.
16. Gaxiola E, Browne KF. Coronary artery perforation repair using microcoil embolization. Cathet Cardiovasc Diagn1998;43:474-6.
17. Albiero R, Nishida T, Corvaja N, Vaghetti M, Di Mario C, et al. Left internal mammary artery graft perforation repair using
polytetrafluoroethylene -covered stents. Cathet Cardiovasc Intervent 2000;51:78-82.
18. Mahmud E, Douglas JS. Coil embolization for successful treatment of perforation of chronically occluded proximal coronary artery.
Cathet Cardiovasc Intervent 2001;53:549-52.
19. Assali AR, Moustapha A, Sdringola S, Rihner M, Smalling RW. Successful treatment of coronary artery perforation in an abciximab-
treated patient by microcoil embolization. Catheter Cardiovasc Interv 2000;51:487-9.
20. Aslam MS, Messersmith RN, Gilbert J, Lakier JB. Successful management of coronary artery perforation with helical platinum
microcoil embolization. Cathet Cardiovasc Intervent 2000;51:320-2.
21. Dixon SR, Webster MWI, Ormiston JA, Wattie WJ, Hammett CJK. Gelfoam embolization of a distal coronary artery guidewire
perforation. Cathet Cardiovasc Intervent 2000;49:214-7.
22. Yoo B, Yoon J, Lee SH, Kim JY, Lee HH, et al. Guidewire-induced coronary artery perforation treated with transcatheter injection of
polyvinyl alcohol foam. Cathet Cardiovasc Intervent 2001;52:231-4.
23. Alfonso F, Goicolea J, Herna´ndez R, Ferna´ndez-Ortiz A, Segovia J, et al. Arterial perforation during optimization of coronary stents
using high-pressure ballon inflations. Am J Cardiol 1996;78:1169-72.
24. Teng MM, Chen CC, Lirng JF, Chen SS, Lee LS, et al. N-butyl-2- (NBCA-MS)-based for embolization of carotid aneurysm.
Neuroradiology 1994;36:144-7
25. Luo CB, Teng MM, Chang FC, Chang CY. Transarterial balloon-assisted n-butyl-2- (NBCA-MS)-based embolization of direct carotid
cavernous fistulas. AJNR Am J Neuroradiol 2006;27:1535-40.
26. Romero-Castro R, Pellicer-Bautista FJ, Jimenez-Saenz M, Marcos-Sanchez F, Caunedo-Alvarez A, et al. EUS-Guided injection of
(NBCA-MS)-based in perforating feeding veins of gastric varices: Results in 5 cases. Gastrointest Endosc 2007;66:402-7.
27. Goel PK, Modi N, Baijal SS, Kathuria M, Agrawal SK. Sonographically guided thrombin injection for the treatment of femoral artery
pseudoaneurysm. Indian Heart J 2003;55:365-7.
28. Olivari Z, Rubartelli P, Piscione F, Ettori F, Fontanelli A, et al. Immediate results and one-year clinical outcome after percutaneous
coronary interventions in chronic total occlusions: data from a multicenter, prospective, observational study (TOAST-GISE). J Am Coll
Cardiol 2003;41:1672-8.
29. Terashima M, Fujiwara S, Yaginuma GY, Takizawa K, Kaneko U, et al. Outcome of percutaneous intrapericardial fibrin-glue injection
therapy for left ventricular free wall rupture secondary to acute myocardial infarction. Am J Cardiol 2008;101:419-21.
30. Fujimatsu T, Oosawa H, Takai F, Aruga M, Ogiwara F, et al. Patch-and-glue sutureless repair for blowout rupture after myocardial
infarction: report of 2 cases. Ann Thorac Cardiovasc Surg 2008;14:48-51
31. Goel PK. Delayed and repeated cardiac tamponade following microleak in RCA successfully treated with intra-arterial sterile glue
injection. Catheter Cardiovasc Interv 2009;73:797-800.
32. Gasparini GL, Merella P, Mazzarotto P, Gagnor A, Garbo R, et al. Retrograde approach-related epicardial collateral channel perforation
successfully treated with simultaneous bilateral coils embolization: a case illustration and review. Cardiovasc Revasc Med 2018;19:879-
86.
33. Hannah Hill, Jeffrey Forris Beecham Chick, Anthony Hage, Ravi N. Srinivasa. N-butyl cyanoacrylate embolotherapy: techniques,
complications, and management. Diagn Interv Radiol. 2018;24:98-103.
34. Kakaei F, Seyyed Sadeghi MS, Sanei B, Hashemzadeh S, Habibzadeh. A randomized clinical trial comparing the effect of different
haemostatic agents for haemostasis of the liver after hepatic resection. HPB Surg 2013;2013:587608.
35. Arvin R. Wali, Charlie C. Park, David R. Santiago-Dieppa, Florin Vaida, James D. Murphy, et al. Pipeline embolization device
versus coiling for the treatment of large and giant unruptured intracranial aneurysms: a cost-effectiveness analysis. Neurosurg Focus
2017;42:E6.