               93.       Chadwick SL, Khaw R, Duncan J, Wilson SW, Highton L, O’Ceallaigh S. The use of venous anastomotic flow couplers to monitor
                    buried free DIEP flap reconstructions following nipple-sparing mastectomy. JPRAS Open 2020;23:50-4.  DOI  PubMed  PMC
               94.       Smit  JM,  Whitaker  IS,  Liss  AG,  Audolfsson  T,  Kildal  M,  Acosta  R.  Post  operative  monitoring  of  microvascular  breast
                    reconstructions using the implantable cook-swartz doppler system: a study of 145 probes & technical discussion. J Plast Reconstr
                    Aesthet Surg 2009;62:1286-92.  DOI  PubMed
               95.       Rozen WM, Ang GG, McDonald AH, et al. Sutured attachment of the implantable doppler probe cuff for large or complex pedicles in
                    free tissue transfer. J Reconstr Microsurg 2011;27:99-102.  DOI  PubMed
               96.       Hayler R, Low TH, Fung K, Nichols AC, MacNeil SD, Yoo J. Implantable doppler ultrasound monitoring in head and neck free
                    flaps: balancing the pros and cons. Laryngoscope 2021;131:E1854-9.  DOI  PubMed
               97.       Um GT, Chang J, Louie O, et al. Implantable cook-swartz doppler probe versus Synovis flow coupler for the post-operative
                    monitoring of free flap breast reconstruction. J Plast Reconstr Aesthet Surg 2014;67:960-6.  DOI
               98.       Kempton SJ, Poore SO, Chen JT, Afifi AM. Free flap monitoring using an implantable anastomotic venous flow coupler: analysis of
                    119 consecutive abdominal-based free flaps for breast reconstruction. Microsurgery 2015;35:337-44.  DOI  PubMed
               99.       Frost MW, Niumsawatt V, Rozen WM, Eschen GE, Damsgaard TE, Kiil BJ. Direct comparison of postoperative monitoring of free
                    flaps with microdialysis, implantable cook-swartz doppler probe, and clinical monitoring in 20 consecutive patients. Microsurgery
                    2015;35:262-71.  DOI  PubMed
               100.      Hosein RC, Cornejo A, Wang HT. Postoperative monitoring of free flap reconstruction: a comparison of external doppler
                    ultrasonography and the implantable doppler probe. Plast Surg 2016;24:11-9.  DOI  PubMed  PMC
               101.      Hirigoyen MB, Blackwell KE, Zhang WX, Silver L, Weinberg H, Urken ML. Continuous tissue oxygen tension measurement as a
                    monitor of free-flap viability. Plast Reconstr Surg 1997;99:763-73.  DOI  PubMed
               102.      Gosain A, Rabkin J, Reymond JP, Jensen JA, Hunt TK, Upton RA. Tissue oxygen tension and other indicators of blood loss or organ
                    perfusion during graded hemorrhage. Surgery 1991;109:523-32.  PubMed
               103.      Gottrup F, Firmin R, Chang N, Goodson WH 3rd, Hunt TK. Continuous direct tissue oxygen tension measurement by a new method
                    using an implantable silastic tonometer and oxygen polarography. Am J Surg 1983;146:399-403.  DOI  PubMed
               104.      Trignano E, Fallico N, Fiorot L, et al. Flap monitoring with continuous oxygen partial tension measurement in breast reconstructive
                    surgery: a preliminary report. Microsurgery 2018;38:402-6.  DOI
               105.      Clark LC Jr. Measurement of oxygen tension: a historical perspective. Crit Care Med 1981;9:690-2.  DOI  PubMed
               106.      Liss AG, Liss P. Use of a modified oxygen microelectrode and laser-doppler flowmetry to monitor changes in oxygen tension and
                    microcirculation in a flap. Plast Reconstr Surg 2000;105:2072-8.  DOI
               107.      Hunt TK, Rabkin J, Jensen JA, Jonsson K, von Smitten K, Goodson WH 3rd. Tissue oximetry: an interim report. World J Surg
                    1987;11:126-32.  DOI  PubMed
               108.      Chang N, Goodson WH 3rd, Gottrup F, Hunt TK. Direct measurement of wound and tissue oxygen tension in postoperative patients.
                    Ann Surg 1983;197:470-8.  DOI  PubMed  PMC
               109.      Gottrup F, Firmin R, Hunt TK, Mathes SJ. The dynamic properties of tissue oxygen in healing flaps. Surgery 1984;95:527-36.  DOI
                    PubMed
               110.      Schrey A, Niemi T, Kinnunen I, et al. The limitations of tissue-oxygen measurement and positron emission tomography as additional
                    methods for postoperative breast reconstruction free-flap monitoring. J Plast Reconstr Aesthet Surg 2010;63:314-21.  DOI
               111.      Mccraw JB, Myers B, Shanklin KD. The value of fluorescein in predicting the viability of arterialized flaps. Plast Reconstr Surg
                    1977;60:710-9.  DOI  PubMed
               112.      Adelsberger R, Fakin R, Mirtschink S, Forster N, Giovanoli P, Lindenblatt N. Bedside monitoring of free flaps using ICG-
                                                                                        #
                    fluorescence angiography significantly improves detection of postoperative perfusion impairment . J Plast Surg Hand Surg
                    2019;53:149-54.  DOI  PubMed
               113.      Nagata T, Masumoto K, Uchiyama Y, et al. Improved technique for evaluating oral free flaps by pinprick testing assisted by
                    indocyanine green near-infrared fluorescence angiography. J Craniomaxillofac Surg 2014;42:1112-6.  DOI
               114.      Hitier M, Cracowski JL, Hamou C, Righini C, Bettega G. Indocyanine green fluorescence angiography for free flap monitoring: a
                    pilot study. J Craniomaxillofac Surg 2016;44:1833-41.  DOI  PubMed
               115.      Su CT, Im MJ, Hoopes JE. Tissue glucose and lactate following vascular occlusion in island skin flaps. Plast Reconstr Surg
                    1982;70:202-5.  DOI  PubMed
               116.      Bashir MM, Tayyab Z, Afzal S, Khan FA. Diagnostic accuracy of blood glucose measurements in detecting venous compromise in
                    flaps. J Craniofac Surg 2015;26:1492-4.  DOI  PubMed
               117.      Karakawa R, Yoshimatsu H, Narushima M, Iida T. Ratio of blood glucose level change measurement for flap monitoring. Plast
                    Reconstr Surg Glob Open 2018;6:e1851.  DOI  PubMed  PMC
               118.      Dickson MG, Sharpe DT. Continuous subcutaneous tissue pH measurement as a monitor of blood flow in skin flaps: an experimental
                    study. Br J Plast Surg 1985;38:39-42.  DOI  PubMed
               119.      Sakakibara S, Hashikawa K, Omori M, Terashi H, Tahara S. A simplest method of flap monitoring. J Reconstr Microsurg
                    2010;26:433-4.  DOI  PubMed
               120.      Hara H, Mihara M, Iida T, et al. Blood glucose measurement for flap monitoring to salvage flaps from venous thrombosis. J Plast
                    Reconstr Aesthet Surg 2012;65:616-9.  DOI
               121.      Henault B, Pluvy I, Pauchot J, Sinna R, Labruère-Chazal C, Zwetyenga N. Capillary measurement of lactate and glucose for free flap