Page 68 - Read Online
P. 68
Page 16 of 17 Cevallos et al. Plast Aesthet Res 2023;10:30 https://dx.doi.org/10.20517/2347-9264.2023.01
93. Chadwick SL, Khaw R, Duncan J, Wilson SW, Highton L, O’Ceallaigh S. The use of venous anastomotic flow couplers to monitor
buried free DIEP flap reconstructions following nipple-sparing mastectomy. JPRAS Open 2020;23:50-4. DOI PubMed PMC
94. Smit JM, Whitaker IS, Liss AG, Audolfsson T, Kildal M, Acosta R. Post operative monitoring of microvascular breast
reconstructions using the implantable cook-swartz doppler system: a study of 145 probes & technical discussion. J Plast Reconstr
Aesthet Surg 2009;62:1286-92. DOI PubMed
95. Rozen WM, Ang GG, McDonald AH, et al. Sutured attachment of the implantable doppler probe cuff for large or complex pedicles in
free tissue transfer. J Reconstr Microsurg 2011;27:99-102. DOI PubMed
96. Hayler R, Low TH, Fung K, Nichols AC, MacNeil SD, Yoo J. Implantable doppler ultrasound monitoring in head and neck free
flaps: balancing the pros and cons. Laryngoscope 2021;131:E1854-9. DOI PubMed
97. Um GT, Chang J, Louie O, et al. Implantable cook-swartz doppler probe versus Synovis flow coupler for the post-operative
monitoring of free flap breast reconstruction. J Plast Reconstr Aesthet Surg 2014;67:960-6. DOI
98. Kempton SJ, Poore SO, Chen JT, Afifi AM. Free flap monitoring using an implantable anastomotic venous flow coupler: analysis of
119 consecutive abdominal-based free flaps for breast reconstruction. Microsurgery 2015;35:337-44. DOI PubMed
99. Frost MW, Niumsawatt V, Rozen WM, Eschen GE, Damsgaard TE, Kiil BJ. Direct comparison of postoperative monitoring of free
flaps with microdialysis, implantable cook-swartz doppler probe, and clinical monitoring in 20 consecutive patients. Microsurgery
2015;35:262-71. DOI PubMed
100. Hosein RC, Cornejo A, Wang HT. Postoperative monitoring of free flap reconstruction: a comparison of external doppler
ultrasonography and the implantable doppler probe. Plast Surg 2016;24:11-9. DOI PubMed PMC
101. Hirigoyen MB, Blackwell KE, Zhang WX, Silver L, Weinberg H, Urken ML. Continuous tissue oxygen tension measurement as a
monitor of free-flap viability. Plast Reconstr Surg 1997;99:763-73. DOI PubMed
102. Gosain A, Rabkin J, Reymond JP, Jensen JA, Hunt TK, Upton RA. Tissue oxygen tension and other indicators of blood loss or organ
perfusion during graded hemorrhage. Surgery 1991;109:523-32. PubMed
103. Gottrup F, Firmin R, Chang N, Goodson WH 3rd, Hunt TK. Continuous direct tissue oxygen tension measurement by a new method
using an implantable silastic tonometer and oxygen polarography. Am J Surg 1983;146:399-403. DOI PubMed
104. Trignano E, Fallico N, Fiorot L, et al. Flap monitoring with continuous oxygen partial tension measurement in breast reconstructive
surgery: a preliminary report. Microsurgery 2018;38:402-6. DOI
105. Clark LC Jr. Measurement of oxygen tension: a historical perspective. Crit Care Med 1981;9:690-2. DOI PubMed
106. Liss AG, Liss P. Use of a modified oxygen microelectrode and laser-doppler flowmetry to monitor changes in oxygen tension and
microcirculation in a flap. Plast Reconstr Surg 2000;105:2072-8. DOI
107. Hunt TK, Rabkin J, Jensen JA, Jonsson K, von Smitten K, Goodson WH 3rd. Tissue oximetry: an interim report. World J Surg
1987;11:126-32. DOI PubMed
108. Chang N, Goodson WH 3rd, Gottrup F, Hunt TK. Direct measurement of wound and tissue oxygen tension in postoperative patients.
Ann Surg 1983;197:470-8. DOI PubMed PMC
109. Gottrup F, Firmin R, Hunt TK, Mathes SJ. The dynamic properties of tissue oxygen in healing flaps. Surgery 1984;95:527-36. DOI
PubMed
110. Schrey A, Niemi T, Kinnunen I, et al. The limitations of tissue-oxygen measurement and positron emission tomography as additional
methods for postoperative breast reconstruction free-flap monitoring. J Plast Reconstr Aesthet Surg 2010;63:314-21. DOI
111. Mccraw JB, Myers B, Shanklin KD. The value of fluorescein in predicting the viability of arterialized flaps. Plast Reconstr Surg
1977;60:710-9. DOI PubMed
112. Adelsberger R, Fakin R, Mirtschink S, Forster N, Giovanoli P, Lindenblatt N. Bedside monitoring of free flaps using ICG-
#
fluorescence angiography significantly improves detection of postoperative perfusion impairment . J Plast Surg Hand Surg
2019;53:149-54. DOI PubMed
113. Nagata T, Masumoto K, Uchiyama Y, et al. Improved technique for evaluating oral free flaps by pinprick testing assisted by
indocyanine green near-infrared fluorescence angiography. J Craniomaxillofac Surg 2014;42:1112-6. DOI
114. Hitier M, Cracowski JL, Hamou C, Righini C, Bettega G. Indocyanine green fluorescence angiography for free flap monitoring: a
pilot study. J Craniomaxillofac Surg 2016;44:1833-41. DOI PubMed
115. Su CT, Im MJ, Hoopes JE. Tissue glucose and lactate following vascular occlusion in island skin flaps. Plast Reconstr Surg
1982;70:202-5. DOI PubMed
116. Bashir MM, Tayyab Z, Afzal S, Khan FA. Diagnostic accuracy of blood glucose measurements in detecting venous compromise in
flaps. J Craniofac Surg 2015;26:1492-4. DOI PubMed
117. Karakawa R, Yoshimatsu H, Narushima M, Iida T. Ratio of blood glucose level change measurement for flap monitoring. Plast
Reconstr Surg Glob Open 2018;6:e1851. DOI PubMed PMC
118. Dickson MG, Sharpe DT. Continuous subcutaneous tissue pH measurement as a monitor of blood flow in skin flaps: an experimental
study. Br J Plast Surg 1985;38:39-42. DOI PubMed
119. Sakakibara S, Hashikawa K, Omori M, Terashi H, Tahara S. A simplest method of flap monitoring. J Reconstr Microsurg
2010;26:433-4. DOI PubMed
120. Hara H, Mihara M, Iida T, et al. Blood glucose measurement for flap monitoring to salvage flaps from venous thrombosis. J Plast
Reconstr Aesthet Surg 2012;65:616-9. DOI
121. Henault B, Pluvy I, Pauchot J, Sinna R, Labruère-Chazal C, Zwetyenga N. Capillary measurement of lactate and glucose for free flap