Page 67 - Read Online
P. 67

Cevallos et al. Plast Aesthet Res 2023;10:30  https://dx.doi.org/10.20517/2347-9264.2023.01  Page 15 of 17

                    imaging of recipient vessels in microsurgery. Plast Reconstr Surg 1999;104:1656-65.  DOI
               63.       Khouri RK, Shaw WW. Monitoring of free flaps with surface-temperature recordings: is it reliable? Plast Reconstr Surg
                    1992;89:495-502.  DOI  PubMed
               64.       Kraemer R, Lorenzen J, Knobloch K, et al. Free flap microcirculatory monitoring correlates to free flap temperature assessment. J
                    Plast Reconstr Aesthet Surg 2011;64:1353-8.  DOI
               65.       Papillion P, Wong L, Waldrop J, et al. Infrared surface temperature monitoring in the postoperative management of free tissue
                    transfers. Can J Plast Surg 2009;17:97-101.  DOI
               66.       Chiu ES, Altman A, Allen RJ Jr, Allen RJ Sr. Free flap monitoring using skin temperature strip indicators: adjunct to clinical
                    examination. Plast Reconstr Surg 2008;122:144e-5e.  DOI  PubMed
               67.       Rabbani MJ, Bhatti AZ, Shahzad A. Flap monitoring using thermal imaging camera: a contactless method. J Coll Physicians Surg
                    Pak 2021;30:703-6.  DOI
               68.       Chang K, Yoon S, Sheth N, et al. Rapid vs. delayed infrared responses after ischemia reveal recruitment of different vascular beds.
                    Quant Infrared Thermogr J 2015;12:173-83.  DOI  PubMed  PMC
               69.       Salgado CJ, Moran SL, Mardini S. Flap monitoring and patient management. Plast Reconstr Surg 2009;124:e295-302.  DOI  PubMed
               70.       Busic V, Das-Gupta R. Temperature monitoring in free flap surgery. Br J Plast Surg 2004;57:588.  DOI  PubMed
               71.       Dam H, Nduka C, Carver N. No touch free-flap temperature monitoring. Br J Plast Surg 2003;56:835.  DOI  PubMed
               72.       Ricci JA, Vargas CR, Lin SJ, Tobias AM, Taghinia AH, Lee BT. A novel free flap monitoring system using tissue oximetry with text
                    message alerts. J Reconstr Microsurg 2016;32:415-20.  DOI  PubMed
               73.       Engel H, Huang JJ, Tsao CK, et al. Remote real-time monitoring of free flaps via smartphone photography and 3G wireless internet: a
                    prospective study evidencing diagnostic accuracy. Microsurgery 2011;31:589-95.  DOI
               74.       Semple JL, Sharpe S, Murnaghan ML, Theodoropoulos J, Metcalfe KA. Using a mobile app for monitoring post-operative quality of
                    recovery of patients at home: a feasibility study. JMIR Mhealth Uhealth 2015;3:e18.  DOI  PubMed  PMC
               75.       Yuen JC. Enabling Remote monitoring using free apps and smart devices for a free-flap adjunct monitor. Plast Reconstr Surg Glob
                    Open 2017;5:e1507.  DOI  PubMed  PMC
               76.       Kiranantawat K, Sitpahul N, Taeprasartsit P, et al. The first smartphone application for microsurgery monitoring: silpaRamanitor.
                    Plast Reconstr Surg 2014;134:130-9.  DOI
               77.       Provenzano D, Chandawarkar A, Caterson E. Abstract QS14: novel smartphone-based free flap monitoring tool using machine
                    learning. Plast Reconstr Surg Glob Open 2019;7:111-2.  DOI  PMC
               78.       Phillips CJ, Barron MR, Kuckelman J, et al. Mobile smartphone thermal imaging characterization and identification of microvascular
                    flow insufficiencies in deep inferior epigastric artery perforator free flaps. J Surg Res 2021;261:394-9.  DOI
               79.       Zaman T, Kyriacou PA, Pal SK. Free flap pulse oximetry utilizing reflectance photoplethysmography. Annu Int Conf IEEE Eng Med
                    Biol Soc 2013;2013:4046-9.  DOI  PubMed
               80.       Keller A. Noninvasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg 2007;23:189-97.  DOI  PubMed
               81.       Menick FJ. The pulse oximeter in free muscle flap surgery. “a microvascular surgeon's sleep aid”. J Reconstr Microsurg 1988;4:331-
                    4.  DOI  PubMed
               82.       Hallock GG, Rice DC. A comparison of pulse oximetry and laser doppler flowmetry in monitoring sequential vascular occlusion in a
                    rabbit ear model. Can J Plast Surg 2003;11:11-4.  DOI
               83.       Lin SJ, Nguyen MD, Chen C, et al. Tissue oximetry monitoring in microsurgical breast reconstruction decreases flap loss and
                    improves rate of flap salvage. Plast Reconstr Surg 2011;127:1080-5.  DOI
               84.       Lohman RF, Langevin CJ, Bozkurt M, Kundu N, Djohan R. A prospective analysis of free flap monitoring techniques: physical
                    examination, external Doppler, implantable Doppler, and tissue oximetry. J Reconstr Microsurg 2013;29:51-6.  DOI  PubMed
               85.       Ozturk CN, Ozturk C, Ledinh W, et al. Variables affecting postoperative tissue perfusion monitoring in free flap breast
                    reconstruction. Microsurgery 2015;35:123-8.  DOI
               86.       Keller A. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen
                    saturation measurements. Ann Plast Surg 2009;62:538-43.  DOI
               87.       Kovalenko B, Roskosky M, Freedman BA, Shuler MS. Effect of ambient light on near infrared spectroscopy. Available from: https://
                    w  w  w  . s e m  a n t i c s c h o l a r . o r g / p a p e r / E f f e c t - o f - A  m  b i e n t - L i g h t - o n - N  e a r - I n f r a r e d - K  o v a l e n k o - R o s k o s k y /
                    b8c2924e0008466beb67d41b18af5809aad9ef77. [Last accessed on 25 Jul 2023]
               88.       Lindelauf AAMA, Vranken NPA, Rutjens VGH, et al. Economic analysis of noninvasive tissue oximetry for postoperative
                    monitoring of deep inferior epigastric perforator flap breast reconstruction: a review. Surg Innov 2020;27:534-42.  DOI  PubMed
                    PMC
               89.       Johnson BM, Cullom ME, Egan KG, et al. Comparing tissue oximetry to doppler monitoring in 1,367 consecutive breast free flaps.
                    Microsurgery 2023;43:57-62.  DOI
               90.       Lu D, Moritz W, Arafa HM, et al. Intramuscular microvascular flow sensing for flap monitoring in a porcine model of arterial and
                    venous occlusion. J Reconstr Microsurg 2023;39:231-7.  DOI
               91.       Ricci JA, Vargas CR, Ho OA, Lin SJ, Tobias AM, Lee BT. Evaluating the use of tissue oximetry to decrease intensive unit
                    monitoring for free flap breast reconstruction. Ann Plast Surg 2017;79:42-6.  DOI  PubMed
               92.       Swartz WM JN, Cherup L, Klein A. Direct monitoring of microvascular anastomoses with the 20-MHZ ultrasonic doppler probe: an
                    experimental and clinical study. Plast Reconstr Surg 1988;81:149-58.  DOI