Page 67 - Read Online
P. 67
Cevallos et al. Plast Aesthet Res 2023;10:30 https://dx.doi.org/10.20517/2347-9264.2023.01 Page 15 of 17
imaging of recipient vessels in microsurgery. Plast Reconstr Surg 1999;104:1656-65. DOI
63. Khouri RK, Shaw WW. Monitoring of free flaps with surface-temperature recordings: is it reliable? Plast Reconstr Surg
1992;89:495-502. DOI PubMed
64. Kraemer R, Lorenzen J, Knobloch K, et al. Free flap microcirculatory monitoring correlates to free flap temperature assessment. J
Plast Reconstr Aesthet Surg 2011;64:1353-8. DOI
65. Papillion P, Wong L, Waldrop J, et al. Infrared surface temperature monitoring in the postoperative management of free tissue
transfers. Can J Plast Surg 2009;17:97-101. DOI
66. Chiu ES, Altman A, Allen RJ Jr, Allen RJ Sr. Free flap monitoring using skin temperature strip indicators: adjunct to clinical
examination. Plast Reconstr Surg 2008;122:144e-5e. DOI PubMed
67. Rabbani MJ, Bhatti AZ, Shahzad A. Flap monitoring using thermal imaging camera: a contactless method. J Coll Physicians Surg
Pak 2021;30:703-6. DOI
68. Chang K, Yoon S, Sheth N, et al. Rapid vs. delayed infrared responses after ischemia reveal recruitment of different vascular beds.
Quant Infrared Thermogr J 2015;12:173-83. DOI PubMed PMC
69. Salgado CJ, Moran SL, Mardini S. Flap monitoring and patient management. Plast Reconstr Surg 2009;124:e295-302. DOI PubMed
70. Busic V, Das-Gupta R. Temperature monitoring in free flap surgery. Br J Plast Surg 2004;57:588. DOI PubMed
71. Dam H, Nduka C, Carver N. No touch free-flap temperature monitoring. Br J Plast Surg 2003;56:835. DOI PubMed
72. Ricci JA, Vargas CR, Lin SJ, Tobias AM, Taghinia AH, Lee BT. A novel free flap monitoring system using tissue oximetry with text
message alerts. J Reconstr Microsurg 2016;32:415-20. DOI PubMed
73. Engel H, Huang JJ, Tsao CK, et al. Remote real-time monitoring of free flaps via smartphone photography and 3G wireless internet: a
prospective study evidencing diagnostic accuracy. Microsurgery 2011;31:589-95. DOI
74. Semple JL, Sharpe S, Murnaghan ML, Theodoropoulos J, Metcalfe KA. Using a mobile app for monitoring post-operative quality of
recovery of patients at home: a feasibility study. JMIR Mhealth Uhealth 2015;3:e18. DOI PubMed PMC
75. Yuen JC. Enabling Remote monitoring using free apps and smart devices for a free-flap adjunct monitor. Plast Reconstr Surg Glob
Open 2017;5:e1507. DOI PubMed PMC
76. Kiranantawat K, Sitpahul N, Taeprasartsit P, et al. The first smartphone application for microsurgery monitoring: silpaRamanitor.
Plast Reconstr Surg 2014;134:130-9. DOI
77. Provenzano D, Chandawarkar A, Caterson E. Abstract QS14: novel smartphone-based free flap monitoring tool using machine
learning. Plast Reconstr Surg Glob Open 2019;7:111-2. DOI PMC
78. Phillips CJ, Barron MR, Kuckelman J, et al. Mobile smartphone thermal imaging characterization and identification of microvascular
flow insufficiencies in deep inferior epigastric artery perforator free flaps. J Surg Res 2021;261:394-9. DOI
79. Zaman T, Kyriacou PA, Pal SK. Free flap pulse oximetry utilizing reflectance photoplethysmography. Annu Int Conf IEEE Eng Med
Biol Soc 2013;2013:4046-9. DOI PubMed
80. Keller A. Noninvasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg 2007;23:189-97. DOI PubMed
81. Menick FJ. The pulse oximeter in free muscle flap surgery. “a microvascular surgeon's sleep aid”. J Reconstr Microsurg 1988;4:331-
4. DOI PubMed
82. Hallock GG, Rice DC. A comparison of pulse oximetry and laser doppler flowmetry in monitoring sequential vascular occlusion in a
rabbit ear model. Can J Plast Surg 2003;11:11-4. DOI
83. Lin SJ, Nguyen MD, Chen C, et al. Tissue oximetry monitoring in microsurgical breast reconstruction decreases flap loss and
improves rate of flap salvage. Plast Reconstr Surg 2011;127:1080-5. DOI
84. Lohman RF, Langevin CJ, Bozkurt M, Kundu N, Djohan R. A prospective analysis of free flap monitoring techniques: physical
examination, external Doppler, implantable Doppler, and tissue oximetry. J Reconstr Microsurg 2013;29:51-6. DOI PubMed
85. Ozturk CN, Ozturk C, Ledinh W, et al. Variables affecting postoperative tissue perfusion monitoring in free flap breast
reconstruction. Microsurgery 2015;35:123-8. DOI
86. Keller A. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen
saturation measurements. Ann Plast Surg 2009;62:538-43. DOI
87. Kovalenko B, Roskosky M, Freedman BA, Shuler MS. Effect of ambient light on near infrared spectroscopy. Available from: https://
w w w . s e m a n t i c s c h o l a r . o r g / p a p e r / E f f e c t - o f - A m b i e n t - L i g h t - o n - N e a r - I n f r a r e d - K o v a l e n k o - R o s k o s k y /
b8c2924e0008466beb67d41b18af5809aad9ef77. [Last accessed on 25 Jul 2023]
88. Lindelauf AAMA, Vranken NPA, Rutjens VGH, et al. Economic analysis of noninvasive tissue oximetry for postoperative
monitoring of deep inferior epigastric perforator flap breast reconstruction: a review. Surg Innov 2020;27:534-42. DOI PubMed
PMC
89. Johnson BM, Cullom ME, Egan KG, et al. Comparing tissue oximetry to doppler monitoring in 1,367 consecutive breast free flaps.
Microsurgery 2023;43:57-62. DOI
90. Lu D, Moritz W, Arafa HM, et al. Intramuscular microvascular flow sensing for flap monitoring in a porcine model of arterial and
venous occlusion. J Reconstr Microsurg 2023;39:231-7. DOI
91. Ricci JA, Vargas CR, Ho OA, Lin SJ, Tobias AM, Lee BT. Evaluating the use of tissue oximetry to decrease intensive unit
monitoring for free flap breast reconstruction. Ann Plast Surg 2017;79:42-6. DOI PubMed
92. Swartz WM JN, Cherup L, Klein A. Direct monitoring of microvascular anastomoses with the 20-MHZ ultrasonic doppler probe: an
experimental and clinical study. Plast Reconstr Surg 1988;81:149-58. DOI