Page 291 - Read Online
P. 291

Page 4 of 11                                           Jeong et al. Mini-invasive Surg 2019;3:38  I  http://dx.doi.org/10.20517/2574-1225.2019.42






























               Figure 1. Surgical gloves as a reservoir. Powder free surgical glove can be used as a reservoir instead of Airseal system. Using a pair of
               gloves is good enough and provides stable pneumo-rectum/pelvis during transanal procedures




































               Figure 2. Solo surgery using a camera holder. Inevitable jam during single port laparoscopic surgery can be solved by applying the solo
               surgery. With the help of a camera holder fixed to rail of bed, the operator can use the space freely for stable procedures

               Once perforation occurs, suture is possible even under TAMIS conditions, so it can be repaired by
               transanal manipulation. However, if the injury is large or there is already contamination of the abdominal
               cavity by the intestinal contents, repair and lavage may be necessary by the transabdominal approach. In
               this case, a single port laparoscopic procedure is usually preferred. Once the transabdominal approach is
               added, the length of stay is usually longer.
   286   287   288   289   290   291   292   293   294   295   296