Page 16 - Read Online
P. 16
Page 1688 Scattini et al. Extracell Vesicles Circ Nucleic Acids. 2026;7:1681-704
Antibody list: anti-GFP diluted 1:7,500 (A6455, Life Technologies, Carlsbad, CA, USA), anti-Alix diluted
1:500 (sc-271975, Santa Cruz Biotechnology, Santa Cruz, CA, USA), anti-Mitofilin diluted 1:8,000 (ab109424,
Abcam, Cambridge, MA, USA), anti-GAPDH diluted 1:10,000 (GTX627408, GeneTex, Irvine, CA, USA),
anti-Syntenin diluted 1:8,000 (SDCBP) (ab62530, Abcam, Cambridge, MA, USA), anti-CD81 diluted 1:200
(sc-166029, Santa Cruz Biotechnology, Santa Cruz, CA, USA), goat anti-mouse immunoglobulin G (IgG)
HRP-conjugated diluted 1:10,000 (A90-116P, Fortislife, Boston, MA, USA), and goat anti-rabbit IgG HRP-
conjugated diluted 1:10,000 (A120-101P, Fortislife, Boston, MA, USA).
Flow cytometry
To compare samples, an equal amount of starting material was used, and EVs isolated from transfected and
untransfected MSCs were analyzed by flow cytometry to assess the presence of GFP-positive events. Based
on particle count data, we diluted EV preparations in 0.22 micrometer-filtered PBS to achieve an identical
final concentration of 10 particles/mL across all samples. For Triton X-100 treatment, vesicles were pre-
7
incubated with 1% (v/v) Triton X-100 on ice for 1 h before dilution. Samples were acquired on a flow
cytometer equipped with 405 and 488 nm lasers (CytoFlex; Beckman Coulter, Brea, CA, USA). The flow
cytometer was calibrated with a mixture of FITC-positive polystyrene beads (Megamix-Plus FSC and SSC
beads; BioCytex, Marseille, France) to identify particles in the nanometric (100, 160, 200, 240, 300, 500 and
900 nm) range in the Violet SSC-H and FITC-H channels. For each diluted sample, 50 µL of each sample was
acquired at a constant flow rate of 10 µL/min for 5 min. After exclusion of background signal in
untransfected controls, GFP-positive events were identified by applying a defined fluorescence gate in the
FITC channel. Data were expressed as the number of GFP-positive events within the FITC-positive gate.
Details on the gating strategy, instrument calibration, and Triton X-100 controls are provided in
Supplementary Figure 1.
Electron microscopy
EV preparations were assessed by electron microscopy. Aliquots of the vesicle suspensions (10 µL) were
deposited as individual droplets onto a sheet of Parafilm, and a formvar-coated nickel grid (Electron
Microscopy Sciences, Hatfield, PA, USA) was laid face-down onto each droplet and left for 30 min to allow
adsorption inside a humidified chamber.
For scanning electron microscopy (SEM), grids were subsequently mounted onto metal stubs. Samples were
sputter-coated with a 10 nm chromium layer and observed with a ZEISS-LEO 1525 scanning electron
microscope (Laboratorio Universitario di Nanomateriali, University of Perugia).
For transmission electron microscopy (TEM), after adsorption, grids were rinsed sequentially in PBS and
distilled water, negatively stained with 2% uranyl acetate for 5 min, and air-dried. Samples were examined
using a Philips EM208 transmission electron microscope equipped with a digital camera (CUMEF -
University Centre of Electron Microscopy and Fluorescent Microscopy, University of Perugia).
Endothelial cell culture and angiogenesis assays
Cell cultures
Human umbilical vein endothelial cells (HUVECs) were purchased from PromoCell GmbH (Heidelberg,
Germany). Cells were cultured in Endothelial Growth Medium (EGM) (PromoCell GmbH) supplemented
with 10% (v/v) FBS (Thermo Fisher Scientific Inc., Waltham, MA, USA) and maintained at 37 °C in a
humidified atmosphere with 5% CO . All experiments were performed using cells between passages 5 and 7.
2

