Page 4 of 9 Horch et al. Plast Aesthet Res 2018;5:26 I http://dx.doi.org/10.20517/2347-9264.2018.25
Figure 2. The 75-year-old patient with intraoperative raised distally based peroneus brevis muscle with flap turned and flipped over to
180 degrees into defect zone of a chronic wound after open reduction and internal fixation of calcaneal fracture
Figure 3. Primary closure of donor site with distally based peroneus brevis muscle flap sutured into place before skin grafting