Page 20 - Read Online
P. 20

Page 14 of 15         Gunderson et al. Plast Aesthet Res 2023;10:50  https://dx.doi.org/10.20517/2347-9264.2023.42

               were not collected to provide in text.


               CONCLUSIONS
               The present study provides essential anatomic data for creating an ovine osseointegrated prosthesis with
               sensory feedback, based on the accepted gold standard sheep model of osseointegration. These data inform
               the manufacture of a sensory ONI for chronic testing in awake, freely ambulating large animals for future
               clinical translation.

               DECLARATIONS
               Acknowledgments
               We would like to acknowledge the University of Wisconsin Surgery Histology Core and the University of
               Wisconsin Translational Research Initiatives in Pathology group for their assistance with histology slide
               creation and image analysis.

               Authors’ contributions
               Concept, design, data collection/analysis, manuscript drafting: Gunderson KA, Dingle AM
               Concept, design, data collection/analysis, manuscript revision: Odorico SK, Nkana ZH,  Zeng W
               Data collection/analysis, manuscript revision: Sears L, Seils G
               Concept, design, figure creation, manuscript revision: Minor RL
               Concept, design, data analysis, manuscript revision: Poore SO


               Availability of data and materials
               Data and materials from this study will be provided upon request.


               Financial support and sponsorship
               None.


               Conflicts of interest
               All authors declared that there are no conflicts of interest.


               Ethical approval and consent to participate
               In accordance with the University of Wisconsin-Madison Institutional Animal. Care and Use Committee’s
               ethics policies, the ethical review was not required to undertake this research.

               Consent for publication
               Not applicable.

               Copyright
               © The Author(s) 2023.


               REFERENCES
               1.       Millevolte AXT, Dingle AM, Ness JP, et al. Improving the selectivity of an osseointegrated neural interface: proof of concept for
                   housing sieve electrode arrays in the medullary canal of long bones. Front Neurosci 2021;15:613844.  DOI  PubMed  PMC
               2.       Karczewski AM, Dingle AM, Poore SO. The need to work arm in arm: calling for collaboration in delivering neuroprosthetic limb
                   replacements. Front Neurorobot 2021;15:711028.  DOI  PubMed  PMC
               3.       Dingle AM, Ness JP, Novello J, et al. Methodology for creating a chronic osseointegrated neural interface for prosthetic control in
                   rabbits. J Neurosci Methods 2020;331:108504.  DOI
               4.       Dingle AM, Ness JP, Novello J, et al. Experimental basis for creating an osseointegrated neural interface for prosthetic control: a pilot
                   study in rabbits. Mil Med 2020;185:462-9.  DOI
   15   16   17   18   19   20   21   22   23   24   25