               in the arterial phase followed by a precocious and marked washout in the portal phase, the nodule is highly
               suspected of ICC; HCC, however, shows a moderate washout in the portal phase and, sometimes, can show
               iso-enhancing compared to surrounding parenchyma. These results have provided the last evidence to reprove
                                  [80]
               the opinion of AASLD .
                                                                       [82]
               The meta-analysis with evidence from 1998 to 2016 of Zhang et al.  showed that CEUS was a useful diag-
               nostic instrument for distinguishing HCC from other FLLs and, in conclusion, could also become a front line
                                                         [83]
                                                                        [84]
               imaging instrument in the future. Masuzaky et al.  and Chan et al.  reported that CEUS has an important
               role in patient candidates to the treatment with radiofrequency ablation (RFA), increasing the detection of
               HCC that are not seen or poor seen on B-mode US and provides real-time guidance of RFA with good short-
               term treatment responses. Intrinsic limitations of CEUS vary in relation to patient characteristics (cooperation,
               obesity, meteorism), characteristics of lesion (site-dimesions-depth) and the CEUS experienced operator.

               Another important limitation of CEUS compared to cross sectional image formation is that only one FLL can
               be evaluated at a time and the repeated administration in bolus of SonoVue is necessary to evaluate other FLLs.
               However, in clinical practice, only 2 and 3 FLLs situated in the same segment lobe can be simultaneously and
                                      [85]
               easily examined with CEUS . On CEUS, the evaluation of enhancement is statistically significant in relation
               to the depth; in particular, at a depth greater than 9 cm from abdominal wall, only 58% of FLL present the
               same arterial enhancement compared to the corresponding phase in multi-slice CT; this contrasts with 95% of
                                              [86]
               the lesions situated more superficially .
               Some studies have demonstrated that a number of lesions, varying 5%-25%, remain unterminated after CEUS,
                                                          [86]
               because they do not present a characteristic pattern . Contrast-enhancing agents until today have not dem-
               onstrated cardio-, hepatic- or nephro-toxic effects. It is not necessary to carry out laboratory tests to evaluate
               hepatic or renal function before their administration. There is limited data about use during pregnancy, breast-
                                                        [87]
               feeding or in pediatrics. In a retrospective study  of 23,188 investigations with SonoVue the rate of serious
               adverse events was only 0.0086% (29 cases), including a pseudo- anaphylactic shock and a bronchospasm, but
               there were no fatalities.


               CONCLUSION
               CEUS is a non invasive, rapid, economical and accurate method for the diagnosis and management of HCC
               in cirrhotic patients; moreover it is repeatable, less stressful and less invasive for the patients and doesn’t re-
               quire exposure to radiation. CEUS is not nephro-toxic and is non allergenic. When the nodular lesions are
               controlled in the cirrhotic liver, CEUS allows a rapid characterization with good precision when carried out
               by a medical expert.



               DECLARATIONS
               Authors’ contributions
               Designed the work, collection and data analysis, critical revision of the article and final approval of the ver-
               sion to be published: Loria F, Parlati A, Loria G
               Contributed to the execution of the ultrasound examination and to the interpretation of the results and to
               the bibliographic research: Loria F, Parlati A, Loria G, Frosina L, Crea G, Basile S, Alessio C, Di Leo G, De
               Caridi A, Maschio V, Zizzi N, Trapuzzano O, Galea SG
               Contribuited also to revision of the article: Loria F, Parlati A, Loria G, Frosina L, Crea G, Basile S, Alessio C,
               Di Leo G, De Caridi A
               Contributed also to drafting the article: Loria F, Parlati A, Loria G, Maschio V, Zizzi N, Trapuzzano O, Galea
               SG
   86   87   88   89   90   91   92   93   94   95   96