Ragni et al. Extracell Vesicles Circ Nucleic Acids. 2026;7:73-93                     Page 77





               NTA analysis
               Pre-sorted samples were diluted in 0.22 µm-filtered PBS to enable comparison with post-sorted samples
               based on the concentration measured by nanoparticle tracking analysis (NTA). Briefly, samples were
               analyzed using the NanoSight NS300 system (NanoSight Ltd., Amesbury, UK). For each sample, five 60 s
               videos were recorded. Data were processed with NTA software to obtain particle concentration and
               high-resolution size distribution profiles.

               EVs characterization by flow cytometry
               Pre-sorted samples were diluted in 0.22 µm-filtered PBS to enable comparison with post-sorted samples
               based on the acquired events/ml. Briefly, prior to use, each Ab was centrifuged at 15,000-17,000 × g for
               30 min at 4 °C to remove aggregates that may cause false-positive signals. Then, Abs were filtered through
               separate 0.22 µm centrifugal filter units at 1,000 × g and 4 °C until the entire volume passed through and no
               liquid remained on the filter surface. Samples, already CFSE-labeled, were divided into 100 μL aliquots. One
               aliquot was left unstained and the other aliquots were separately incubated for 30 min at 4 °C in the dark
               with 5 μL of allophycocyanin (APC)-conjugated Abs: anti-CD9 (312107, BioLegend Europe B.V.,
               Amsterdam, The Netherlands), CD63 (353007, BioLegend), CD81 (349509, BioLegend), CD90 (328113,
               BioLegend), or CD73 (344005, BioLegend). One-hundred μL aliquots of PBS were similarly processed for Ab
               background control. After staining, 200 μL of 0.22 µm-filtered PBS were added to each sample. Acquisition
               and recording were performed with a low flow rate (10 µL per min) using a CytoFLEX flow cytometer. All
               sample volumes were acquired. Instrument settings were established using Megamix-Plus SSC + FSC
               reference beads (Biocytex, Marseille, France), composed of FITC-labeled polystyrene beads of 100, 160, 200,
               240, 300, 500 and 900 nm in diameter. The FITC threshold was optimized to include 100 nm beads and
               smaller particles in the FITC/CFSE channel.

               EV isolation and RNA extraction
               Post-sorted EVs (5-10 mL) and a volume of pre-sorted conditioned media equivalent to that used for sorting
               were ultracentrifuged using a protocol previously established in our laboratory, which efficiently recovers
               nanoparticles without selectively enriching specific subpopulations relative to the input . Briefly, both
                                                                                            [15]
               pre-sorted and post-sorted samples were supplemented with 0.22 µm-filtered PBS up to 10 mL and
               centrifuged at 100,000 × g for 9 h at 4 °C in an Optima L-90K equipped with a Fixed-angle titanium rotor,
               Type 70.1 Ti (Beckman Coulter). Pellets were washed with 10 mL of 0.22 µm-filtered PBS and centrifuged
               under the same conditions. After carefully removing all remaining liquid, pellets were dissolved with QIAzol
               Lysis Reagent and total RNA extracted with miRNeasy Micro Kit (Qiagen, Hilden, Germany) following the
               manufacturer’s instructions. Due to the very low particle number, it was not possible to quantify RNA for
               sequencing, so all extracted nucleic acids were processed. RNA was stored at -80 °C until use.


               miRNAs profiling and data analysis
               SMARTer smRNA (miRNA). Next-generation sequencing (NGS) libraries were prepared using the
               SMARTer smRNA-seq Kit (Cat N° 635031; TaKaRa, Mountain View, CA, USA) for Illumina. Briefly,
               isolated small RNAs were converted into complementary DNA (cDNA), followed by barcoding using the
               recommended number of polymerase chain reaction (PCR) cycles. The quality and quantity of the small
               RNA libraries were assessed using the Agilent 4200 TapeStation system. Libraries were then diluted and
               sequenced on the Illumina NovaSeq 6000 platform (Illumina, San Diego, CA, USA), targeting an average
               depth of 15-20 million reads per library with a read length of 100 nucleotides. Raw sequencing data were
               demultiplexed using the Bcl2Fastq software (Illumina, Inc., USA).


               Differential expression of ASC-EVs and sASC-EVs-derived miRNAs
               Raw reads, consisting of 100-bp single-end reads, were trimmed to remove adapters and artefacts and keep
               only those with at least 15 nt, with cutadapt (https://cutadapt.readthedocs.io/en/stable/, v4.4) . Then, they
                                                                                              [16]