Page 38 - Read Online
P. 38
Page 307 Gaspari et al. Extracell Vesicles Circ Nucleic Acids. 2026;7:302-27
Conditioned medium production
At P3, cell medium was changed to serum-free culture medium maintaining the same atmospheric
conditions. CM was obtained by collecting the cell medium every 24 h and replacing it with fresh serum-free
medium, for 3 days. To remove possible detached cells, CM was centrifuged at 1,600 × g for 20 min and at
4,500 × g for 20 min to remove debris. Finally, CM was stored at -80 °C until EV isolation.
Extracellular vesicle isolation and characterization
EVs were isolated by ultracentrifugation of CM at 100,000 × g (Beckman Coulter OptimaX, Milan, Italy),
4 °C for 1 h and the obtained pellet was resuspended in serum-free medium. Vesicles were characterized
according to Minimal Information for Studies of Extracellular Vesicles (MISEV) guidelines .
[31]
Nanoparticle tracking analysis
EV size and concentration were assessed by nanoparticle tracking analysis (NTA) performed using a
NanoSight NS300 system (Malvern Technologies, Malvern, UK), configured with a 532 nm laser, following
the manufacturer’s instructions. A syringe pump with constant flow injection was used, and three videos of
60 s each were captured and analyzed with NTA software update v3.44. From each video, the mean, mode
and median EV sizes were used to calculate sample concentration expressed in nanoparticles/mL.
Western blot and BCA assay
This analysis was performed to identify specific markers typical of EVs. A volume of 32 μL of each sample
was treated with 8 μL of Laemmli buffer under reducing conditions, and the mixture was heated at 95 °C for
10 min. The sample was loaded onto a sodium dodecyl sulfate-polyacrylamide gel electrophoresis
(SDS-PAGE, 4%-20%, Mini-PROTEAN TGX Precast Protein Gel, Bio-Rad) and run under an electric field
before being transferred to a nitrocellulose membrane (Bio-Rad, Trans-Blot Turbo, Milan, Italy). A blocking
step was performed to saturate nonspecific sites: 1 h with 5% (w/v) bovine serum albumin (BSA) in T-TBS
(tris-buffered saline: 150 mM NaCl, 20 mM Tris-HCl, pH 7.4 and 0.5% Tween 20). After, the membranes
were incubated overnight at 4 °C on an orbital shaker with primary antibodies, polyclonal antibody
anti-tumor susceptibility gene 101 (TSG101) (1:500 dilution, Invitrogen, Monza, Italy), monoclonal antibody
anti-Alix (1:1,000 dilution, Santa Cruz, CA, USA), monoclonal antibody anti-CD81 (1:500 dilution, Santa
Cruz, CA, USA) and monoclonal antibody anti-CD63 (1:500 dilution, BD Biosciences New Jersey, USA).
Strips were washed for 5 min, 3 times with Tris-buffered saline with Tween 20 (TBS-T), after which
membranes were incubated with horseradish peroxidase (HRP)-conjugated, anti-mouse secondary antibody
(Bio-Rad) diluted 1:3,000 in TBS-T with 1% BSA. Final washes were performed, and the signal was detected
using Bio-Rad Clarity Western ECL Substrate (Bio-Rad) and imaged using a Chemidoc XRS+ (Bio-Rad).
To ensure the purity of the EV sample, comparative quantification of total protein [via bicinchoninic acid
(BCA) assay] and Western blot analysis between EVs and AMCs was performed to assess the absence of
Calnexin, typical marker for cell lysates. A pellet sample of P3 AMCs (10 cells) was lysed using
6
radio-immunoprecipitation assay (RIPA) buffer (Thermo Fisher) supplemented with Halt Protease Inhibitor
(1×) according to the manufacturer’s protocol. A sample of EV suspension was mixed with RIPA buffer at a
1:1 ratio and supplemented with Halt Protease Inhibitor (1×). Samples were briefly sonicated and gently
mixed for 30 min, then centrifuged at 14,000 × g for 15 min. Supernatants were transferred to fresh vials and
protein concentration was determined using the BCA assay (Pierce ). Supernatants were diluted 1:25 for the
TM
AMC sample and 1:5 for the EV sample prior to measurement. After correcting for dilution, the total protein
concentration was 2,146.6 µg/mL for the AMC sample and 458.2 µg/mL for the EV sample. Both samples
were adjusted to the same concentration using Laemmli buffer (5×, reducing conditions) to allow loading of
16 µg of total protein per lane. A volume of 10 µL of Precision Plus All-Blue protein standards (Bio-Rad) and
45 µL of each prepared sample were loaded per lane onto Bio-Rad TGX gradient gels (4%-15%), separated by