Page 27 - Read Online
P. 27
Scattini et al. Extracell Vesicles Circ Nucleic Acids. 2026;7:1681-704 Page 1699
the EV surface should be considered a critical design parameter when developing engineered EV-based
delivery platforms.
From a translational perspective, these findings support the development of modular EV-based delivery
platforms, in which peptide size, orientation, and mode of presentation can be optimized according to the
intended biological function. The identification of a minimal angiogenic motif that remains active after EV
incorporation may facilitate the design of more controllable and standardized EV formulations.
Study limitations and future perspectives
In this proof-of-concept study, our primary objective was to demonstrate in vitro the technological feasibility
of displaying engineered functional peptides on the EV surface to drive angiogenesis.
While the long-term goal of this platform is its translational application as a therapeutic nanocarrier, a
limitation of the present study is that it remains confined to an in vitro setting. Several intermediate steps will
therefore be required before in vivo application can be considered. Mechanistic studies addressing receptor
engagement, binding kinetics, and internalization dynamics of the EV-displayed peptides, as discussed
below, will be essential to substantiate the proposed mode of action. In addition, more complex,
physiologically relevant models - such as 3D co-culture or ex vivo tissue explant systems - could help bridge
the gap between simplified 2D endothelial assays and the multicellular, dynamic environment of native
tissue. Indeed, the wound healing (scratch) and tube formation assays employed here, while widely used and
informative, remain surrogate, single-cell-type readouts of angiogenesis; they do not capture the contribution
of pericytes, immune cells, or extracellular matrix remodeling that shape the angiogenic response in vivo, and
the present results should be interpreted within this constraint.
Moreover, the functional characterization of the engineered EVs was restricted to HUVECs; potential off-
target effects on other cell populations present in the wound microenvironment, such as fibroblasts or
resident immune cells, were not investigated and should be addressed in future safety-oriented studies.
Dose-response and pharmacokinetic characterization, together with assessment of EV stability and
reproducibility across production batches, and robustness of the engineering strategy across different MSC
biological backgrounds, will also be necessary before translational application can be considered.
Closely related to this, the manufacturing scalability of this EV-engineering approach has not been addressed
in the present study; translating peptide-displaying EVs from small-scale laboratory production to a large-
scale, GMP-compliant process suitable for clinical development represents an additional, non-trivial
technical hurdle.
Moreover, in vivo validation will require the prior identification of a disease-relevant setting - including the
specific pathological condition and animal model best suited to test this platform. Extending the platform in
this direction could represent a valuable line of future work.
The rational design of EV-based delivery platforms relies on translating known bioactive motifs onto a
nanovesicular scaffold. We previously demonstrated that angiogenesis induced by the p17-derived fragments
F2 and F3 37-52 requires distinct receptors - CXCR1, CXCR2, and the βc receptor [24,26] . Consequently, each
engineered construct may exhibit unique surface docking, entry kinetics, and downstream crosstalk.
Although the interaction and internalization of MSC-derived EVs by endothelial cells are well-established
phenomena [38-40] and our functional readouts confirm that EV-displayed peptides successfully trigger
angiogenic responses, a current limitation of this study is the lack of precise molecular mechanisms and
receptor-mediated dynamics for the EV-displayed constructs.