﻿<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "http://jats.nlm.nih.gov/publishing/1.0/JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta>
      <journal-id journal-id-type="nlm-ta">Microstructures</journal-id>
      <journal-id journal-id-type="publisher-id">MICROSTRUCTURES</journal-id>
      <journal-title-group>
        <journal-title>Microstructures</journal-title>
      </journal-title-group>
      <issn pub-type="epub">2770-2995</issn>
      <publisher>
        <publisher-name>OAE Publishing Inc.</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
	<article-id pub-id-type="doi">10.20517/microstructures.2026.142</article-id>
      <article-categories>
        <subj-group>
          <subject>Research Article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>High-performance self-powered X-ray detection materials based on KTiOAsO<sub>4</sub> polar crystals</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Hu</surname>
            <given-names>Yifan</given-names>
          </name>
          <xref ref-type="aff" rid="I1">
            <sup>1</sup>
          </xref>
          <xref ref-type="aff" rid="I2">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author" corresp="yes">
          <name>
            <surname>Sun</surname>
            <given-names>Wenting</given-names>
          </name>
          <xref ref-type="aff" rid="I1">
            <sup>1</sup>
          </xref>
          <xref ref-type="corresp" rid="cor1" />
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Feng</surname>
            <given-names>Xiaozheng</given-names>
          </name>
          <xref ref-type="aff" rid="I2">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Hu</surname>
            <given-names>Fuai</given-names>
          </name>
          <xref ref-type="aff" rid="I2">
            <sup>2</sup>
          </xref>
        </contrib>
        <contrib contrib-type="author" corresp="yes">
          <name>
            <surname>Gao</surname>
            <given-names>Zeliang</given-names>
          </name>
          <xref ref-type="aff" rid="I2">
            <sup>2</sup>
          </xref>
          <xref ref-type="corresp" rid="cor1" />
        </contrib>
      </contrib-group>
      <aff id="I1">
        <sup>1</sup>School of Electronics and Integrated Circuits, Aerospace Information Technology University, Jinan 250200, Shandong, China.</aff>
      <aff id="I2">
        <sup>2</sup>State Key Laboratory of Crystal Materials and Institute of Crystal Materials, Shandong University, Jinan 250100, Shandong, China.</aff>
      <author-notes>
        <corresp id="cor1">Correspondence to: Dr. Wenting Sun, School of Electronics and Integrated Circuits, Aerospace Information Technology University, No. 2 Daxue Road, Zhangqiu District, Jinan 250200, Shandong, China. E-mail: <email>sunwenting@aitech.edu.cn</email>; Dr. Zeliang Gao, State Key Laboratory of Crystal Materials, Shandong University, Jinan 250100, Shandong, China. E-mail: <email>gaozeliang@sdu.edu.cn</email></corresp>
      <fn fn-type="other">
          <p>
            <bold>Received:</bold> 12 Jun 2026 | <bold>First Decision:</bold> 21 Jul 2026 | <bold>Revised:</bold> 28 Aug 2026 | <bold>Accepted:</bold> 28 Aug 2026 | <bold>Published:</bold> 23 Oct 2026</p>
        </fn>
        <fn fn-type="other">
          <p>
            <bold>Academic Editor:</bold> Chunqiang Zhuang | <bold>Copy Editor:</bold> Fangling Lan |  <bold>Production Editor:</bold> Fangling Lan</p>
        </fn>
      </author-notes>
	  <pub-date pub-type="ppub">
        <year>2026</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>23</day>
        <month>10</month>
        <year>2026</year>
      </pub-date>
      <volume>6</volume>
	  <issue>6</issue>
	 <elocation-id>20260134</elocation-id>
	 
	 
	 
      <permissions>
        <copyright-statement>© The Author(s) 2026.</copyright-statement>
        <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <license-p>© The Author(s) 2026. <bold>Open Access</bold> This article is licensed under a Creative Commons Attribution 4.0 International License (<uri xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</uri>), which permits unrestricted use, sharing, adaptation, distribution and reproduction in any medium or format, for any purpose, even commercially, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.</license-p>
        </license>
      </permissions>
      <abstract>
        <p>Self-powered X-ray detectors can perform X-ray inspections without requiring an external power supply, enabling the design of highly portable X-ray detection devices. As a result, they hold broad application prospects in the fields of industrial non-destructive testing and medical examinations. This paper reports a self-powered X-ray detector based on a KTiOAsO<sub>4</sub> polar crystal, which possesses a strong built-in electric field (approximately <InlineParagraph>40 V·mm<sup>-1</sup>)</InlineParagraph> capable of separating photo-generated carriers. The detector operates efficiently without requiring an external bias, thereby reducing power consumption and simplifying the device structure. Under zero-bias conditions, the detector achieves a sensitivity of up to <InlineParagraph>110.72 μC·Gy<sub>air</sub><sup>-1</sup>·cm<sup>-2</sup></InlineParagraph> along the Y-axis, with a detection limit as low as 0.061 μGy<sub>air</sub>·s<sup>-1</sup> along the X-axis, demonstrating excellent low-dose imaging. When the applied bias voltage was increased to 200 V, the sensitivity in the Y-axis direction reached a maximum of <InlineParagraph>192.96 μC·Gy<sub>air</sub><sup>-1</sup>cm<sup>-2</sup></InlineParagraph> (70 keV), indicating excellent radiation detection performance. Furthermore, its high ion activation energy <InlineParagraph>(&gt; 200 meV</InlineParagraph> along the Y direction of the principal axis) suppresses ion migration, effectively preventing performance degradation and ensuring long-term stability. The anisotropic carrier-transport characteristics allow selection of the optimal crystal orientation based on specific application requirements. This study demonstrates that this well-established nonlinear optical crystal can serve as an X-ray detection material for medical imaging and trace radiation detection, providing an experimental foundation for its use as a low-power, high-performance radiation detection platform.</p>
      </abstract>
      <kwd-group>
        <kwd>X-ray detectors</kwd>
        <kwd>polar oxide crystals</kwd>
        <kwd>self-powered X-ray detector</kwd>
        <kwd>built-in electric field</kwd>
        <kwd>anisotropy</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec id="sec1">
      <title>INTRODUCTION</title>
      <p>By interacting with electrons in the object being examined, X-rays can carry information about that object through changes in signal intensity<sup>[<xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B2">2</xref>]</sup>. Thus, direct detection of changes in X-rays allows accurate retrieval of information about the subject<sup>[<xref ref-type="bibr" rid="B3">3</xref>-<xref ref-type="bibr" rid="B5">5</xref>]</sup>. The two most widely used types of X-ray detectors are direct and indirect detectors. Indirect X-ray detectors consist of two main parts: the scintillator material converts the incident X-rays into photons, and the photoelectric sensor converts the optical signal into an electrical signal<sup>[<xref ref-type="bibr" rid="B6">6</xref>]</sup>. Direct X-ray detectors directly convert X-ray signals into electrical signals. They effectively reduce signal attenuation and, compared to indirect detectors, offer higher spatial resolution and superior image quality, thereby demonstrating significant technical advantages<sup>[<xref ref-type="bibr" rid="B7">7</xref>-<xref ref-type="bibr" rid="B12">12</xref>]</sup>. Currently, most high-performance direct X-ray detectors are made of inorganic semiconductor materials, such as silicon, germanium, selenium, cadmium-zinc-tellurium, and chalcogenides<sup>[<xref ref-type="bibr" rid="B13">13</xref>]</sup>. These detection materials demonstrate exceptional performance in X-ray detection; however, their application is constrained by a number of limitations, primarily including severe X-ray attenuation, low damage thresholds, high operating voltages, significant noise levels, severe baseline drift, high costs, and contamination issues during the manufacturing process<sup>[<xref ref-type="bibr" rid="B14">14</xref>-<xref ref-type="bibr" rid="B18">18</xref>]</sup>. In addition, significant progress has been made in organic and inorganic materials, such as MAPbI<sub>3</sub>, MAPbBr<sub>3</sub>, CsPbBr<sub>3</sub>, and MA<sub>3</sub>Bi<sub>2</sub><sup>[<xref ref-type="bibr" rid="B19">19</xref>-<xref ref-type="bibr" rid="B21">21</xref>]</sup>. These materials contain high-Z elements such as lead (Pb), bismuth (Bi), iodine (I), and bromine (Br), and therefore possess large X-ray absorption cross-sections and excellent carrier transport properties<sup>[<xref ref-type="bibr" rid="B22">22</xref>-<xref ref-type="bibr" rid="B24">24</xref>]</sup>. However, the vast majority of them contain toxic elements, are prone to deliquescence, and are susceptible to decomposition or phase transitions under high-temperature conditions<sup>[<xref ref-type="bibr" rid="B22">22</xref>-<xref ref-type="bibr" rid="B24">24</xref>]</sup>.</p>
      <p>Compared with conventional inorganic X-ray detection materials, oxide crystals can be grown using the flux method, which is favorable for obtaining high-quality bulk single crystals<sup>[<xref ref-type="bibr" rid="B25">25</xref>,<xref ref-type="bibr" rid="B26">26</xref>]</sup>. Compared with organic-inorganic composites, oxide crystals have wider band gaps and stable physicochemical properties, especially their unparalleled high-temperature stability, which gives them a wide operating temperature range and allows them to be used under extreme conditions<sup>[<xref ref-type="bibr" rid="B25">25</xref>-<xref ref-type="bibr" rid="B28">28</xref>]</sup>. Previous studies based on oxide X-ray detection materials have provided important avenues to address these issues. KTiOAsO<sub>4</sub> (KTA) is an oxide crystal with excellent physicochemical stability. Its elemental composition includes elements with medium atomic numbers, such as arsenic (As) and titanium (Ti), giving it appreciable X-ray absorption capacity. Furthermore, KTA crystals can be grown into large, low-defect single crystals using the well-established flux method. Although KTA contains arsenic and requires appropriate protocols during growth and processing to ensure safety, it does not contain highly toxic heavy metals such as lead and cadmium, which are commonly found in many perovskite-based detectors. Furthermore, once crystallized, it is chemically stable and non-toxic during routine use, thereby reducing the risks associated with its manufacture and use. Additionally, KTA exhibits excellent thermal and chemical stability and resistance to phase transitions or decomposition. It is expected to overcome the application limitations of traditional detector materials under extreme conditions, offering a new candidate material for high-performance, environmentally friendly direct X-ray detectors.</p>
      <p>This study systematically investigated the X-ray detection performance of KTA polar crystals, evaluating key metrics including the carrier mobility-lifetime product (μτ), sensitivity, signal-to-noise ratio, and detection limit under both biased and self-powered operating modes. The anisotropic response behavior and its structural origins were also comprehensively analyzed. The results demonstrate that KTA crystals, leveraging their unique polar structure, strong built-in electric field, and excellent physicochemical stability, deliver competitive X-ray detection performance, with notable self-powered capability and effective suppression of ion migration. Its crystal structure and the arrangement of TiO<sub>6</sub> octahedra provide insights into how polar crystal symmetry governs the trade-off between sensitivity and detection limit. These characteristics establish KTA as a promising candidate material for portable, low-dose X-ray detection applications in domains including medical diagnostics, safety inspections, and industrial non-destructive testing.</p>
    </sec>
    <sec id="sec2">
      <title>MATERIALS AND METHODS</title>
      <sec id="sec2-1">
        <title>Materials</title>
        <p>KTA single crystals serving as the core material were grown by our research group. The samples measured 6 × 6 × 2 mm<sup>3</sup>, and no obvious defects were observed. The samples were numbered KTA-X, KTA-Y, and KTA-Z according to the crystal axis perpendicular to the test plane.</p>
      </sec>
      <sec id="sec2-2">
        <title>Detector preparation</title>
        <p>Au electrodes were used for detector fabrication. A physical mask was closely bonded to the KTA crystal, and an Au target with 99.999% purity was used as the sputtering source. The KTA crystal was placed in a vacuum chamber, and sputtering was initiated once the pressure fell below 10 Pa. Using ion sputtering and a physical mask, a 100-nm-thick, 2 × 2 mm<sup>2</sup> gold electrode was deposited onto the crystal surface to fabricate a single-crystal detector. The detector exhibits an Au/KTA/Au structure. This fabrication method is simple to perform and offers good reproducibility.</p>
      </sec>
      <sec id="sec2-3">
        <title>Detector performance characterization</title>
        <p>The X-ray source was an X-ray tube (E7252X, Toshiba, Japan) operated at 40-150 keV; the tube current was adjusted from 10 mA to 100 mA to vary the X-ray dose rate. Current-voltage (I-V) and current-time (I-t) curves were recorded using a 6517B high-precision electrometer (Keithley, USA). Measurements were conducted under optically isolated conditions (in the dark) to ensure that the recorded current originated entirely from X-ray excitation rather than from photo-generated carriers. In X-ray detection, the effective device area (4 mm<sup>2</sup>) is defined as the metal area on the device surface in contact with the probe. All detector performance tests were conducted on unpackaged devices at room temperature.</p>
      </sec>
      <sec id="sec2-4">
        <title>X-ray imaging performance</title>
        <p>The X-ray imaging performance of KTA X-ray detectors was measured on a custom-built platform. The X-ray detector sample used for imaging was coated with a gold electrode with an area of 6 × 6 mm<sup>2</sup> on one side and a planar array electrode on the other side. The area of each small electrode was 0.5 × 0.5 mm<sup>2</sup>, and the distance between the electrodes was 0.1 mm. The imaging object was placed between a planar array X-ray detector and an X-ray beam, and the electrical signals of the detector were recorded at different positions. The imaging object was chosen to be smaller than the planar array detector so that the whole object could be imaged in a single acquisition without moving the detector, thereby avoiding unwanted errors.</p>
      </sec>
    </sec>
    <sec id="sec3">
      <title>RESULTS AND DISCUSSION</title>
      <sec id="sec3-1">
        <title>Crystal properties</title>
        <p>The KTA crystal belongs to the orthorhombic crystal system with space group Pna2<sub>1</sub>, and its polar axis extends along the crystallographic Z-axis. <xref ref-type="fig" rid="fig1">Figure 1A</xref> shows KTA samples (polished on both sides) along three principal axis directions, which were used for the fabrication of X-ray detectors. The device configuration is displayed in <xref ref-type="fig" rid="fig1">Figure 1B</xref>. We further compared the X-ray absorption coefficients of KTA with those of some previously reported X-ray detection materials [<xref ref-type="fig" rid="fig1">Figure 1C</xref>]. Within the typical detection range, the coefficient of KTA crystals is lower than that of Se, Ga<sub>2</sub>O<sub>3</sub>, and CdZnTe due to the smaller atomic numbers of K, As, Ti, and O. Specifically, at 40 keV, a 2-mm-thick KTA crystal absorbs nearly 100% of the incident photons [<xref ref-type="fig" rid="fig1">Figure 1D</xref>]. Resistivity is a key parameter affecting X-ray detection performance. It determines the dark current level of the material, which in turn influences the detector’s sensitivity. To evaluate the resistivity of KTA crystals, we employed the two-probe method to measure the resistivity of KTA samples along different crystal orientations at room temperature. The results reveal that the resistivities along the X, Y, and Z axes are 4.02 × 10<sup>9</sup>, 7.69 × 10<sup>9</sup>, and 5.15 × 10<sup>6</sup> Ω·cm, respectively, exhibiting significant anisotropy [<xref ref-type="fig" rid="fig1">Figure 1E</xref> and <xref ref-type="fig" rid="fig1">F</xref>]. This anisotropy stems from differences in atomic bonding patterns within the crystal structure and the directionality of carrier transport paths. Specifically, the resistivity along the Z-axis (polar axis) is approximately three orders of magnitude lower than that along the X- and Y-axes, indicating that the migration resistance of charge carriers in the Z-axis is lower. However, when the resistivity is too low, it leads to excessively high dark current, and photocurrent shielding effects arise, significantly reducing the detector’s sensitivity and signal-to-noise ratio. This hinders accurate measurements and practical applications [<inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Figure 1</inline-supplementary-material>]. Therefore, polar-axis orientation is not an ideal choice for X-ray detection. To meet the requirements for high signal-to-noise ratio and high sensitivity in practical applications, the non-polar axis directions are the most appropriate choice.</p>
        <fig id="fig1" position="float">
          <label>Figure 1</label>
          <caption>
            <p>(A) Photograph of the KTA samples (original image by the authors). (B) Schematic of the X-ray detector configuration. (C) Comparison of X-ray absorption coefficients between KTA and other materials<sup>[<xref ref-type="bibr" rid="B33">33</xref>]</sup>. (D) Comparison of X-ray attenuation efficiency between KTA and other materials<sup>[<xref ref-type="bibr" rid="B33">33</xref>]</sup>. (E) Resistivity of the KTA crystal along the X and Y axes. (F) Resistivity of the KTA crystal along the Z axis. (G) Carrier mobility-lifetime product of the KTA crystal along the three principal axes.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="microstructures60142.fig.1.jpg" />
        </fig>
        <p>As a key parameter characterizing charge transport capability and carrier extraction efficiency, the carrier mobility-lifetime product (μτ) directly determines the ultimate responsivity and quantum efficiency of photodetectors. To quantitatively evaluate the carrier transport properties of KTA crystals, we systematically investigated their voltage-dependent photoconductive behavior by applying a linearly swept DC bias from 0 to 100 V at an X-ray dose rate of 55.0374 μGy<sub>air</sub>·s<sup>-1</sup> (120 keV). Additionally, the dynamic photocurrent response was simultaneously monitored under dark and X-ray irradiation conditions to determine the field-induced charge collection efficiency. The photocurrent-voltage relationship was fitted using the Hecht equation<sup>[<xref ref-type="bibr" rid="B29">29</xref>]</sup>:</p>
       
	   <p><disp-formula> <label>(1)</label> <tex-math id="E1"> $$ \begin{equation}  \begin{aligned}  I=\frac{I_{0} \mu \tau V}{L^{2}}\left(1-\exp \left(\frac{-L^{2}}{\mu \tau V}\right)\right) \end{aligned} \end{equation} $$ </tex-math>
</disp-formula></p>
	   
        <p>where <italic>I</italic><sub>0</sub> is the saturation current, <italic>µ</italic> is the carrier mobility, <italic>τ</italic> represents the carrier lifetime, <italic>V</italic> is the bias, and <italic>L</italic> is the thickness of the sample. The experimentally measured carrier mobility-lifetime product is shown in <xref ref-type="fig" rid="fig1">Figure 1G</xref>, Note that for a photoresistor-type device with symmetric planar metal-semiconductor-metal contacts, the single-carrier Hecht equation yields an effective μτ value that represents a weighted average of both electron and hole contributions, rather than the μτ of an individual carrier type<sup>[<xref ref-type="bibr" rid="B29">29</xref>-<xref ref-type="bibr" rid="B31">31</xref>]</sup>. This is because, under uniform X-ray excitation throughout the crystal thickness, both electrons and holes are generated and contribute to the measured photocurrent, and the symmetric contact geometry does not provide the carrier selectivity needed to isolate one type<sup>[<xref ref-type="bibr" rid="B32">32</xref>]</sup>. Therefore, the μτ values reported in this paper should be understood as an effective transport parameter characterizing the overall charge collection efficiency of the KTA detector in a photoresistor configuration. To measure the μτ values for electrons and holes independently, it is necessary to employ techniques such as α-particle excitation, which can selectively generate carriers near a specific electrode.</p>
        <p>The high ionic charge density of Ti<sup>4+</sup> and As<sup>5+</sup> in KTA leads to strong Coulombic interactions and large ionic radii, thereby suppressing ion mobility and enhancing lattice stability. Temperature-dependent transient reverse currents of KTA (303-333 K) reveal ion migration dynamics [<inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Figure 2</inline-supplementary-material>]. Under applied bias, field-driven ion migration establishes space-charge polarization until the current reaches steady state. Abrupt voltage removal initiates ion redistribution through vacancy diffusion, producing a concentration-gradient-induced reverse dark current that relaxes to a steady state. Ion activation energies for KTA crystals, fitted along the (100), (010), and (001) planes [<inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Figure 3</inline-supplementary-material>], together with the dark current drifts measured along the polar axis direction [<inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Figure 4</inline-supplementary-material>] collectively demonstrate weak ionic mobility. For comparison, halide perovskite detectors such as MAPbBr<sub>3</sub> exhibit ion activation energies as low as ~73 meV, leading to pronounced dark current drift and performance degradation under applied bias<sup>[<xref ref-type="bibr" rid="B18">18</xref>]</sup>. In contrast, the substantially higher activation energy of KTA (&gt; 200 meV) effectively suppresses field-driven ion migration.</p>
      </sec>
      <sec id="sec3-2">
        <title>X-ray detection with applied bias</title>
        <p>Sensitivity, as a core performance metric for direct-type X-ray detectors, characterizes the detector’s ability to respond to X-ray signals. It is typically quantified by the photocurrent density or charge collection efficiency generated per unit dose of X-ray irradiation. For KTA detectors, their high carrier mobility-lifetime product (μτ) effectively enhances charge collection efficiency and thus improves the conversion of X-ray photons into electrical signals. Furthermore, when oriented along a non-polar axis (such as the X-axis or Y-axis), the high resistivity can significantly suppress the dark current, reducing background noise interference and thereby optimizing the sensitivity. To systematically evaluate the X-ray detection performance of KTA crystals, we measured the current-time (I-T) response curves of KTA detectors over a bias voltage range of 0 to 200 V. <xref ref-type="fig" rid="fig2">Figure 2A</xref> shows the I-T response curves under different bias voltages, and <xref ref-type="fig" rid="fig2">Figure 2B</xref> shows the variation in photocurrent as the X-ray dose rate increases from 2.94 to 7.43 μGy<sub>air</sub>·s<sup>-1</sup>. The results reveal that the carrier transport and collection efficiency increase significantly with rising bias voltage, leading to a corresponding enhancement of the photocurrent response. However, as the voltage rises further, the dark current increases along with the photocurrent. Sensitivity therefore reaches a saturation point, beyond which it no longer improves. Based on the photocurrent data, the detector’s sensitivity can be calculated using the following formula:</p>
       
	   <p><disp-formula> <label>(2)</label> <tex-math id="E1"> $$ \begin{equation}  \begin{aligned}    S=\frac{\Delta I}{(A \times \Delta D)}  \end{aligned} \end{equation} $$ </tex-math>
</disp-formula></p>
	   
       
        <p>where Δ<italic>I</italic> represents the difference between photocurrent and dark current, <italic>A</italic> represents the Au electrode area, and Δ<italic>D</italic> represents the changes in X-ray dose rate. A linear correlation exists between the current density generated under X-ray irradiation and the X-ray dose rate [<xref ref-type="fig" rid="fig2">Figure 2B</xref> and <inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Figure 5</inline-supplementary-material>]. The detector's sensitivity was determined by fitting the slopes of these current density versus dose rate plots at various bias voltages [<xref ref-type="fig" rid="fig2">Figure 2C</xref> and <xref ref-type="fig" rid="fig2">D</xref>]. The experimental data show that the detector exhibits higher sensitivity under lower radiation dose rates. This phenomenon is primarily because the atomic numbers of the elements in KTA are not particularly high, resulting in limited X-ray absorption capacity. Meanwhile, excessively high dose rates lead to premature carrier recombination, which in turn affects the detector’s sensitivity. The maximum sensitivity of the KTA directional X-ray detector is 192.96 μC Gy<sub>air</sub><sup>-1</sup>·cm<sup>-2</sup> (200 V, 70 keV). Under an applied bias voltage of 200 V and an X-ray dose rate range of 17.4432-34.7328 μGy<sub>air</sub>·s<sup>-1</sup>, this value is 9.6 times higher than that of the α-Se detector (20 μC·Gy<sub>air</sub><sup>-1</sup> cm<sup>-2</sup>, measured at 20 keV). Furthermore, the sensitivity exhibits strong voltage dependence. However, when the bias voltage is too high, leakage current increases significantly and carrier recombination becomes severe. At the same time, factors such as breakdown or thermal effects significantly reduce the material’s charge collection efficiency and signal generation capability, so the sensitivity no longer increases with rising voltage.</p>
		
		 <fig id="fig2" position="float">
          <label>Figure 2</label>
          <caption>
            <p>(A) Response of the KTA detector to X-rays at different bias voltages. (B) X-ray photocurrent generated by the KTA detector at different dose rates. (C) Sensitivity of the KTA detector along the X-axis under an applied bias voltage. (D) Sensitivity of the KTA detector along the Y-axis under an applied bias voltage. (E) Stability of the detector after 1,000 s of irradiation. (F) Photocurrent of the detector before and after 30 days of storage at room temperature. (G) Fitted detection limit of the KTA detector at a 50 V bias. (H) Comparison of the performance of KTA and other detector materials under an applied bias<sup>[<xref ref-type="bibr" rid="B30">30</xref>,<xref ref-type="bibr" rid="B32">32</xref>,<xref ref-type="bibr" rid="B34">34</xref>-<xref ref-type="bibr" rid="B42">42</xref>]</sup>.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="microstructures60142.fig.2.jpg" />
        </fig>
		
		
		
        <p>To evaluate the performance stability of the KTA detector under continuous irradiation conditions, we subjected the device to frequent X-ray irradiation at a dose rate of 7.43 μGy<sub>air</sub>·s<sup>-1</sup> and recorded the I-T curves of the switching process over time [<xref ref-type="fig" rid="fig2">Figure 2E</xref>]. Notably, the KTA X-ray detector exhibited high photocurrent and stable dark current characteristics. The unencapsulated device retained 95.5% of its initial photocurrent even after being exposed to air for over 1,000 s. The 4.5% loss can be attributed mainly to electrode damage caused by prolonged probe contact, suggesting that operational stability can be further enhanced by optimizing the contact design. Subsequently, after the device was left at room temperature (25 ± 2 °C in ambient air) for 30 days and retested, the photocurrent density showed no significant decrease [<xref ref-type="fig" rid="fig2">Figure 2F</xref>], confirming its excellent stability under routine conditions. Admittedly, this stability assessment was limited to intermittent irradiation tests. To verify its practical applicability in clinical and industrial settings, a systematic evaluation of long-term operational stability under continuous X-ray irradiation is still required. However, under standard test conditions described above, the photocurrent values remained highly stable throughout the observation period. Based on this, we can cautiously conclude that the KTA detector has the potential for long-term service under standard operating conditions. Extreme or continuous irradiation scenarios remain within the scope of future optimization and validation and do not undermine the validity of the current conclusion.</p>
        <p>The detection limits of KTA detectors are derived from current-time (I-T) curves measured under X-ray exposure. Specifically, the minimum detection limit is defined as the dose rate at which the signal-to-noise ratio (SNR) equals 3<sup>[<xref ref-type="bibr" rid="B30">30</xref>,<xref ref-type="bibr" rid="B31">31</xref>]</sup>. This SNR is calculated using the following equation:</p>
       
	    <p><disp-formula> <label>(3)</label> <tex-math id="E1"> $$ \begin{equation}  \begin{aligned}   S N R=\frac{\left(I_{{photo }}-I_{{dark }}\right)}{\sqrt{\frac{1}{N} \sum_{i}^{n}\left(I_{i}-I_{{photo }}\right)^{2}}} \end{aligned} \end{equation} $$ </tex-math>
</disp-formula></p>
	   
	   
        <p>Where <italic>I<sub>photo</sub></italic> represents the average photocurrent, <italic>I<sub>dark</sub></italic> represents the average dark current without X-ray irradiation, and <italic>I<sub>i</sub></italic> represents the photocurrent. <xref ref-type="fig" rid="fig2">Figure 2G</xref> shows the signal-to-noise ratio of KTA single-crystal detectors. The lowest detection limit of the KTA detector reaches 0.09 μGy<sub>air</sub>·s<sup>-1</sup> (50 V, 40 keV). For comparison, conventional X-ray detectors exhibit detection limits of 5 μGy<sub>air</sub>·s<sup>-1</sup> for α-Se (20 keV)<sup>[<xref ref-type="bibr" rid="B32">32</xref>]</sup>, <InlineParagraph>69.5 μGy<sub>air</sub>·s<sup>-1</sup></InlineParagraph> for β-Ga<sub>2</sub>O<sub>3</sub>:Mg SC (50 keV)<sup>[<xref ref-type="bibr" rid="B34">34</xref>]</sup>, and 9.8 μGy<sub>air</sub>·s<sup>-1</sup> for β-Ga<sub>2</sub>O<sub>3</sub>:Al (50 keV)<sup>[<xref ref-type="bibr" rid="B35">35</xref>]</sup>, and the standard medical test result is 5.5 μGy<sub>air</sub>·s<sup>-1</sup><sup>[<xref ref-type="bibr" rid="B29">29</xref>]</sup>. These lower detection limits demonstrate the potential of KTA X-ray detectors for medical examinations. A comparison of the sensitivity and detection limits of the KTA detector with other reported materials is shown in <xref ref-type="fig" rid="fig2">Figure 2H</xref> and <xref ref-type="table" rid="t1">Table 1</xref>.</p>
        <table-wrap id="t1">
          <label>Table 1</label>
          <caption>
            <p>Comparison of the performance of KTA and other X-ray detectors in the applied voltage mode</p>
          </caption>
          <table frame="hsides" rules="groups">
            <thead>
              <tr>
                <td style="border-bottom:1;">
                  <bold>Materials</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>X-ray energy</bold>
                  <break />
                  <bold>(keV)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>μτ</bold>
                  <break />
                  <bold>(cm<sup>2</sup> V<sup>-1</sup>)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>Sensitivity</bold> <break /><bold>(μC·Gy<sub>air</sub><sup>-1</sup> cm<sup>-2</sup>)</bold></td>
                <td style="border-bottom:1;">
                  <bold>Detection limit</bold>
                  <break />
                  <bold>(μGy<sub>air</sub>·s<sup>-1</sup>)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>Ref</bold>
                </td>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>α-Se</td>
                <td>20</td>
                <td>4 × 10<sup>-7</sup></td>
                <td>20</td>
                <td>5</td>
                <td>[<xref ref-type="bibr" rid="B32">32</xref>]</td>
              </tr>
              <tr>
                <td>β-Ga<sub>2</sub>O<sub>3</sub>:Mg</td>
                <td>50</td>
                <td>-</td>
                <td>338.9</td>
                <td>69.5</td>
                <td>[<xref ref-type="bibr" rid="B34">34</xref>]</td>
              </tr>
              <tr>
                <td>MAPbBr<sub>3</sub></td>
                <td>50</td>
                <td>1.2 × 10<sup>-2</sup></td>
                <td>80</td>
                <td>0.5</td>
                <td>[<xref ref-type="bibr" rid="B30">30</xref>]</td>
              </tr>
              <tr>
                <td>β-Ga<sub>2</sub>O<sub>3</sub>:Al</td>
                <td>50</td>
                <td>-</td>
                <td>851.6</td>
                <td>&lt; 9.8</td>
                <td>[<xref ref-type="bibr" rid="B35">35</xref>]</td>
              </tr>
              <tr>
                <td>Ni-DABDT</td>
                <td>20</td>
                <td>3.26 × 10<sup>-4</sup></td>
                <td>98.6</td>
                <td>7.2</td>
                <td>[<xref ref-type="bibr" rid="B36">36</xref>]</td>
              </tr>
              <tr>
                <td>(FPEA)<sub>4</sub>AgBiBr<sub>8</sub></td>
                <td>40</td>
                <td>-</td>
                <td>27</td>
                <td>2.6</td>
                <td>[<xref ref-type="bibr" rid="B37">37</xref>]</td>
              </tr>
              <tr>
                <td>Cs<sub>2</sub>AgBiBr<sub>6</sub></td>
                <td>50</td>
                <td>1.72 × 10<sup>-3</sup></td>
                <td>105</td>
                <td>0.0597</td>
                <td>[<xref ref-type="bibr" rid="B38">38</xref>]</td>
              </tr>
              <tr>
                <td>Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> </td>
                <td>50</td>
                <td>1.68 × 10<sup>-3</sup></td>
                <td>1,652.3</td>
                <td>0.13</td>
                <td>[<xref ref-type="bibr" rid="B39">39</xref>]</td>
              </tr>
              <tr>
                <td>Cs<sub>2</sub>TeI<sub>6</sub> films</td>
                <td>20</td>
                <td>-</td>
                <td>76.27</td>
                <td>0.17</td>
                <td>[<xref ref-type="bibr" rid="B40">40</xref>]</td>
              </tr>
              <tr>
                <td>Cs<sub>3</sub>Cu<sub>2</sub>I<sub>5</sub></td>
                <td>50</td>
                <td>1.4 × 10<sup>-4</sup></td>
                <td>441.45</td>
                <td>0.335</td>
                <td>[<xref ref-type="bibr" rid="B41">41</xref>]</td>
              </tr>
              <tr>
                <td>TMCM-CdCl<sub>3</sub></td>
                <td>40</td>
                <td>1.42 × 10<sup>-4</sup></td>
                <td>128.9</td>
                <td>1.6</td>
                <td>[<xref ref-type="bibr" rid="B42">42</xref>]</td>
              </tr>
              <tr>
                <td>KTA (Y-axis, 200 V)</td>
                <td>70</td>
                <td>3.98 × 10<sup>-7</sup></td>
                <td>192.96</td>
                <td>1.2</td>
                <td>This work</td>
              </tr>
              <tr>
                <td>KTA (X-axis, 50 V)</td>
                <td>40</td>
                <td>3.97 × 10<sup>-7</sup></td>
                <td>78.8</td>
                <td>0.09</td>
                <td>This work</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec id="sec3-3">
        <title>Self-powered X-ray detection</title>
        <p>By utilizing the intrinsic electric field inherent in KTA, we developed a self-powered X-ray detection technique. The experimental setup is shown in <inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Figure 6</inline-supplementary-material>. This approach efficiently collects and transports charge carriers generated by X-ray excitation, eliminating the need for an external voltage. As shown in <xref ref-type="fig" rid="fig3">Figure 3A</xref>, the dark current is less than 1 pA at 0 V bias, significantly lower than that under an applied bias. Furthermore, at 0 V bias, the detector exhibits both a substantial photocurrent response <InlineParagraph>[<xref ref-type="fig" rid="fig3">Figure 3B</xref>]</InlineParagraph> and excellent stability [<xref ref-type="fig" rid="fig3">Figure 3C</xref>]. As the applied X-ray dose rate was gradually increased from 2.94 to <InlineParagraph>7.43 μGy<sub>air</sub>·s<sup>-1</sup>,</InlineParagraph> the photocurrent density along the Y-axis increased from 0.24 to 0.74 nA·cm<sup>-2</sup>, while that along the X-axis increased from 0.40 to 0.73 nA·cm<sup>-2</sup> [<xref ref-type="fig" rid="fig3">Figure 3D</xref>]. By fitting the slopes, the sensitivity of the KTA detector along the X-axis direction was determined to be 68.84 μC·Gy<sub>air</sub><sup>-1</sup> cm<sup>-2</sup> at 0 V, and along the Y-axis direction, it was 110.72 μC·Gy<sub>air</sub><sup>-1</sup> cm<sup>-2</sup> [<xref ref-type="fig" rid="fig3">Figure 3E</xref>]. This performance improvement is attributed to the unique crystal structure of KTA: under zero-bias conditions, this structure exhibits high carrier mobility and low recombination rates, enabling efficient collection of X-ray-induced carriers. The combination of low dark current and high sensitivity gives KTA detectors an excellent signal-to-noise ratio [<xref ref-type="fig" rid="fig3">Figure 3F</xref>]. The measured detection limits of the KTA detector are 0.113 μGy<sub>air</sub>·s<sup>-1</sup> along the Y-axis direction and <InlineParagraph>0.061 μGy<sub>air</sub>·s<sup>-1</sup></InlineParagraph> along the X-axis direction, both well below the dose rates required for clear medical imaging. Furthermore, the self-powered mode eliminates the risk of electrical breakdown caused by high external bias, significantly enhancing the detector’s long-term stability and safety for clinical use. Consequently, KTA-based self-powered detectors, with their compact structure, low power consumption, and high performance, hold significant application potential in the field of low-dose medical imaging.</p>
        <fig id="fig3" position="float">
          <label>Figure 3</label>
          <caption>
            <p>(A) Dark current of the KTA detector at 0 V bias. (B) Photocurrent response of the KTA detector at 0 V bias. (C) Steady-state photocurrent signal of the KTA detector under continuous X-ray irradiation. (D) Photocurrent density without applied bias. (E) Sensitivity without applied bias. (F) Detection limit without an applied bias. (G and H) Response time of the detector without an applied bias. (I) Comparison of detection performance without an applied bias<sup>[<xref ref-type="bibr" rid="B20">20</xref>,<xref ref-type="bibr" rid="B25">25</xref>,<xref ref-type="bibr" rid="B26">26</xref>,<xref ref-type="bibr" rid="B43">43</xref>-<xref ref-type="bibr" rid="B49">49</xref>]</sup>.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="microstructures60142.fig.3.jpg" />
        </fig>
        <p>In self-powered detectors, no bias voltage is applied, so the dark current is reduced to the lowest level inherent to the material. This characteristic resolves the significant problem of conventional X-ray detectors where both photocurrent and dark current increase simultaneously, and it also reduces photon noise to some extent, thereby lowering the detection limit. In addition, the performance of the KTA detector in self-powered mode surpasses that of many previously reported self-powered X-ray detectors such as GaN<sup>[<xref ref-type="bibr" rid="B43">43</xref>]</sup>, MAPbBr<sub>3</sub><sup>[<xref ref-type="bibr" rid="B44">44</xref>]</sup>, and MhyPbBr<sub>3</sub> (Mhy = methylhydrazine)<sup>[<xref ref-type="bibr" rid="B45">45</xref>]</sup>, in the balance of sensitivity and detection limit. It can thus be concluded that polar oxide crystals exhibit good self-powered detection performance. <xref ref-type="table" rid="t2">Table 2</xref> compare the detection limits of some previously reported self-powered X-ray detectors with those of the KTA self-powered detector. In practical applications, reducing the response time of X-ray detectors not only significantly lowers radiation exposure but also improves imaging efficiency, which fully meets safety requirements in fields such as radiation protection and clinical practice. To this end, we tested the response time of the KTA crystal X-ray detector. <xref ref-type="fig" rid="fig3">Figures 3G</xref> and <xref ref-type="fig" rid="fig3">H</xref> show the photocurrent response time of the KTA X-ray detector at an X-ray energy of 40 keV. In self-powered mode, the response time was approximately 320 ms, indicating a rapid signal response. This ability to effectively capture rapidly changing processes and provide precise time-resolved information for clinical diagnosis or real-time imaging further validates its application potential. Meanwhile, we compared its performance with that of self-powered detectors reported in the literature [<xref ref-type="fig" rid="fig3">Figure 3I</xref>], finding that the KTA detector achieves an effective balance between sensitivity and detection limit.</p>
        <table-wrap id="t2">
          <label>Table 2</label>
          <caption>
            <p>Performance comparison of KTA and other X-ray detectors in self-powered mode</p>
          </caption>
          <table frame="hsides" rules="groups">
            <thead>
              <tr>
                <td style="border-bottom:1;">
                  <bold>Materials</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>X-ray energy</bold>
                  <break />
                  <bold>(keV)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>μτ</bold>
                  <break />
                  <bold>(cm<sup>2</sup> V<sup>-1</sup>)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>Sensitivity (μC·Gy<sub>air</sub><sup>-1</sup> cm <sup>-2</sup>)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>Detection limit</bold>
                  <break />
                  <bold>(μGy<sub>air</sub>·s<sup>-1</sup>)</bold>
                </td>
                <td style="border-bottom:1;">
                  <bold>Ref</bold>
                </td>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>CsPbBr<sub>3</sub> thick film</td>
                <td>35</td>
                <td>-</td>
                <td>470</td>
                <td>0.053</td>
                <td>[<xref ref-type="bibr" rid="B46">46</xref>]</td>
              </tr>
              <tr>
                <td>MAPbBr<sub>3</sub> single crystal</td>
                <td>35</td>
                <td>-</td>
                <td>80</td>
                <td>0.5</td>
                <td>[<xref ref-type="bibr" rid="B44">44</xref>]</td>
              </tr>
              <tr>
                <td>(BA)<sub>2</sub>(MA)<sub>2</sub>Pb<sub>3</sub>I<sub>10</sub> thin film</td>
                <td>10.91</td>
                <td>-</td>
                <td>13</td>
                <td>10</td>
                <td>[<xref ref-type="bibr" rid="B47">47</xref>]</td>
              </tr>
              <tr>
                <td>GaN</td>
                <td>30</td>
                <td>-</td>
                <td>170</td>
                <td />
                <td>[<xref ref-type="bibr" rid="B43">43</xref>]</td>
              </tr>
              <tr>
                <td>(BA)<sub>2</sub>CsAgBiBr<sub>7</sub>/Cs<sub>2</sub>AgBiBr<sub>6</sub> heterojunction</td>
                <td>40</td>
                <td>2.8 × 10<sup>-3</sup></td>
                <td>206</td>
                <td>-</td>
                <td>[<xref ref-type="bibr" rid="B48">48</xref>]</td>
              </tr>
              <tr>
                <td>(3-MNPA)PbBr<sub>4</sub></td>
                <td>30</td>
                <td>3.43 × 10<sup>-3</sup></td>
                <td>123</td>
                <td>0.058</td>
                <td>[<xref ref-type="bibr" rid="B20">20</xref>]</td>
              </tr>
              <tr>
                <td>MhyPbBr<sub>3</sub></td>
                <td>50</td>
                <td>1.1 × 10<sup>-3</sup></td>
                <td>220</td>
                <td>0.2</td>
                <td>[<xref ref-type="bibr" rid="B45">45</xref>]</td>
              </tr>
              <tr>
                <td>α-BTM</td>
                <td>40</td>
                <td>3.2 × 10<sup>-3</sup></td>
                <td>213</td>
                <td>0.112</td>
                <td>[<xref ref-type="bibr" rid="B26">26</xref>]</td>
              </tr>
              <tr>
                <td>β-BTM</td>
                <td>40</td>
                <td>5.89 × 10<sup>-3</sup></td>
                <td>300.2</td>
                <td>0.044</td>
                <td>[<xref ref-type="bibr" rid="B26">26</xref>]</td>
              </tr>
              <tr>
                <td>BaTeW<sub>2</sub>O<sub>9</sub></td>
                <td>120</td>
                <td>4.03 × 10<sup>-3</sup></td>
                <td>404</td>
                <td>0.022</td>
                <td>[<xref ref-type="bibr" rid="B25">25</xref>]</td>
              </tr>
              <tr>
                <td>FAPbBr<sub>3</sub> thin film</td>
                <td>40</td>
                <td>5.09 × 10<sup>-5</sup></td>
                <td>7,280</td>
                <td>0.133</td>
                <td>[<xref ref-type="bibr" rid="B49">49</xref>]</td>
              </tr>
              <tr>
                <td>KTA (Y-axis)</td>
                <td>40</td>
                <td>4 × 10<sup>-7</sup></td>
                <td>110.72</td>
                <td>0.113</td>
                <td>This work</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec id="sec3-4">
        <title>Dipole moment and electrostatic field</title>
        <p>In self-powered mode, the outstanding X-ray detection performance of the KTA detector is attributed to the built-in electric field of the polar crystal, which enables a synergistic combination of high sensitivity, fast response, high stability, and low detection limits. To elucidate the microscopic mechanism underlying the polarity of the KTA crystal, we systematically analyzed the atomic arrangement within the unit cell. The data reveal that the KTA crystal is a polar oxide crystal composed of distorted TiO<sub>6</sub> octahedra and AsO<sub>4</sub> tetrahedra. Its crystallographic parameters, obtained via computational analysis, are detailed in <inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Table 1</inline-supplementary-material>. The distorted TiO<sub>6</sub> octahedra within the unit cell generate intrinsic dipole moments. By performing a vector sum of these dipole moments, we obtained the net dipole moment of a single KTA unit cell. This method directly characterizes the strength of the built-in electric field induced by crystal polarization. The significant dipole moment observed in the KTA crystal [<xref ref-type="fig" rid="fig4">Figure 4A</xref>] provides direct experimental evidence for the presence of a strong built-in electric field, with a measured dipole moment of 25.93 × 10<sup>-4</sup> esu·cm·A<sup>-3</sup>. To quantitatively characterize the built-in electric field strength, we employed a series of positive and negative bias voltage gradients to induce an asymmetric photocurrent response in the device.</p>
        <fig id="fig4" position="float">
          <label>Figure 4</label>
          <caption>
            <p>(A) Orientation of the dipole moments in each TiO<sub>6</sub> polyhedron of KTA. The direction of the net dipole moment is indicated by the red arrow. (B) Photocurrent response along the X-axis under a negative bias. (C) Photocurrent response along the Y-axis under a negative bias. (D) Photocurrent response along the Z-axis under a negative bias.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="microstructures60142.fig.4.jpg" />
        </fig>
        <p>Under experimental conditions, the detector is simultaneously exposed to X-ray irradiation and an applied bias voltage. Gradual voltage tuning enables the identification of the null bias condition for zero photocurrent output. At this equilibrium state, the applied voltage completely counteracts the built-in electric field and eliminates the photocurrent response. The strength of the built-in electric field can then be calculated using the following formula:</p>
       
	    <p><disp-formula> <label>(4)</label> <tex-math id="E1"> $$ \begin{equation}  \begin{aligned}   E_{{built-in }}=\frac{V_{{null }}}{d}  \end{aligned} \end{equation} $$ </tex-math>
</disp-formula></p>
	   
	   
	   
        <p>where <italic>V<sub>null</sub></italic> is the voltage at which the photocurrent vanishes, and <italic>d</italic> is the thickness of the active layer.</p>
        <p>As shown in <xref ref-type="fig" rid="fig4">Figure 4B</xref>-<xref ref-type="fig" rid="fig4">D</xref>, the photocurrent response gradually weakens and eventually disappears as the applied negative voltage increases. Ultimately, the built-in electric field strength of KTA was measured to be 35 V·mm<sup>-1</sup> in the X-axis, 40 V·mm<sup>-1</sup> in the Y-axis, and 4 V·mm<sup>-1</sup> in the Z-axis. This is because KTA crystals exhibit a pronounced multi-domain structure at room temperature; the 180° antiparallel domains along the Z-axis suppress the macroscopic polarization field. Since the crystals were not subjected to deliberate single-domain treatment, the presence of domain walls significantly weakens the built-in electric field along the Z direction<sup>[<xref ref-type="bibr" rid="B50">50</xref>]</sup>.</p>
        <p>The discrepancy between the experimentally measured spontaneous polarization intensity and the calculated unit cell dipole moment may stem from a variety of factors, including local structural distortions, interfacial interactions, and the limitations of the experimental measurements. Despite discrepancies between measured values and theoretical calculations, the overall trend is consistent with the theoretical predictions. It can be concluded that the built-in electric field primarily originates from the material’s spontaneous polarization, while interfacial effects play a secondary role; together, these two factors enable efficient charge extraction and transport in the absence of an applied bias.</p>
      </sec>
      <sec id="sec3-5">
        <title>X-ray imaging</title>
        <p>The above results demonstrate that the built-in electric field in polar oxide crystals can effectively promote carrier transport, thereby enabling excellent self-powered detection performance. Based on this outstanding detection performance, we further evaluated the imaging capabilities of the self-powered KTA detector. We successfully assembled a complete imaging system, whose structure is shown in <xref ref-type="fig" rid="fig5">Figure 5A</xref>. An arrow-shaped metal object (6 mm long × 4.5 mm wide) was selected as the imaging target and placed between the detector and the X-ray source. An X-ray energy of 40 keV was applied [<inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Table 2</inline-supplementary-material>], and imaging tests were conducted in self-powered mode. <xref ref-type="fig" rid="fig5">Figure 5B</xref> presents the X-ray imaging of this arrow-shaped metal object. The image clearly reproduces the arrow’s complete outline and edge details, demonstrating that the KTA crystal self-powered detector possesses excellent spatial resolution. This result is consistent with the fast response and high sensitivity described earlier, indicating that the KTA detector is capable of resolving object features on the submillimeter scale in self-powered mode. However, the current spatial resolution is limited by various factors, including the pixel pitch of the electrodes and the crystal thickness. The pixel pitch determines the limiting resolution of the sampling, while the crystal thickness affects lateral diffusion during charge transport and crosstalk between adjacent pixels. By further optimizing the pixel geometry, adjusting the crystal thickness, and employing collimation techniques, it is expected that the resolution of this detector in practical imaging applications will be significantly improved.</p>
        <fig id="fig5" position="float">
          <label>Figure 5</label>
          <caption>
            <p>(A) KTA crystal plane array imaging system. (B) X-ray imaging results in self-powered mode.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="microstructures60142.fig.5.jpg" />
        </fig>
      </sec>
      <sec id="sec3-6">
        <title>Anisotropy of structure and properties</title>
        <p>As described above, we comprehensively analyzed the performance of the KTA detector under X-ray irradiation at various dose rates. The results indicate that the sensitivity of the KTA detector along the Y-axis is superior to that along the X-axis under all tested dose rates [<xref ref-type="fig" rid="fig6">Figure 6A</xref>-<xref ref-type="fig" rid="fig6">C</xref>]. This phenomenon can be understood by examining the photocurrent response at low dose rates. At the lowest measured dose rate of 2.94 μGy<sub>air</sub>·s<sup>-1</sup>, the photocurrent density along the X-axis (0.40 nA·cm<sup>-2</sup>) was approximately 66.7% higher than the value along the Y-axis direction (0.24 nA·cm<sup>-2</sup>). As the dose rate increased to 7.43 μGy<sub>air</sub>·s<sup>-1</sup>, the photocurrent along the Y-axis became comparable to that along the X-axis (0.74 and 0.73 nA·cm<sup>-2</sup>), which is consistent with the higher overall sensitivity slope along the Y-axis (110.72 and 68.84 μC·Gy<sub>air</sub><sup>-1</sup>·cm<sup>-2</sup>). To explore the underlying causes, we analyzed the crystal structure of the KTA. This anisotropy can be attributed to structural differences along the crystallographic axes: specifically, the parallel, twisted TiO<sub>6</sub> chains along the Y-axis form a highly ordered in-plane network of channels, significantly enhancing charge transport. In contrast, the structure along the X-axis exhibits a more staggered arrangement <InlineParagraph>[<xref ref-type="fig" rid="fig6">Figure 6D</xref> and <xref ref-type="fig" rid="fig6">E</xref>].</InlineParagraph> This difference directly determines the sensitivity of the detector along the different axes. Quantitatively, the Y-axis sensitivity (110.72 μC·Gy<sub>air</sub><sup>-1</sup>·cm<sup>-2</sup>) exceeds that of the X-axis (68.84 μC·Gy<sub>air</sub><sup>-1</sup>·cm<sup>-2</sup>) by approximately 60% in self-powered mode, consistent with the higher built-in electric field and the more continuous charge-transport pathways provided by the parallel TiO<sub>6</sub> chains.</p>
        <fig id="fig6" position="float">
          <label>Figure 6</label>
          <caption>
            <p>(A) Comparison of X- and Y-axis sensitivity of KTA crystals at X-ray dose rates of 2.94-7.43 μGy<sub>air</sub>·s<sup>-1</sup>. (B) at X-ray dose rates of 17.44-34.73 μGy<sub>air</sub>·s<sup>-1</sup>. (C) at X-ray dose rates of 50.04-127.322 μGy<sub>air</sub>·s<sup>-1</sup>. (D) The distorted TiO<sub>6</sub> octahedra in KTA are distributed along the twisted direction of the X-axis. (E) The distorted TiO<sub>6</sub> octahedra in KTA exhibit a parallel distribution along the Y-axis direction.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="microstructures60142.fig.6.jpg" />
        </fig>
        <p>Furthermore, the comprehensive analysis of the experimental data indicates that the lowest detection limit is achieved along the X-axis direction in self-powered mode. This is attributed to a better balance among the built-in electric field strength in the X-axis direction, the charge separation efficiency, and the dark current level. Compared with the stronger built-in electric field along the Y-axis (which may cause slightly higher dark current), the electric field strength along the X-axis ensures that the carrier drift velocity is sufficient to capture weak X-ray signals while effectively suppressing unwanted background current interference. At the same time, although the interlaced crystal structure along the X-axis direction reduces the overall efficiency of charge transport, it also decreases the probability of non-radiative carrier recombination, thereby improving the signal-to-noise ratio for weak signals. The combined effect of these factors enables X-ray detection at lower doses along the X-axis in self-powered mode, thereby achieving the lowest detection limit.</p>
        <p>Experimental results show that the structural anisotropy of KTA crystals determines the anisotropic transport of charge carriers and the distribution of the built-in electric field, thereby influencing the detector’s sensitivity and detection limit. This correlation between structure and performance reveals a key physical principle: by controlling the crystal orientation and structure, the balance between sensitivity and detection limit can be systematically adjusted. This design principle applies not only to KTA but can also be extended to other polar oxide detector materials, providing theoretical guidance for the development of next-generation oriented X-ray detectors tailored to specific application scenarios.</p>
      </sec>
    </sec>
    <sec id="sec4">
      <title>CONCLUSION</title>
      <p>In summary, this study systematically investigated the X-ray detection performance of the nonlinear optical polar oxide crystal KTA and revealed its significant self-powered anisotropic response. Under external bias conditions, the detector’s sensitivity reaches 192.96 μC·Gy<sub>air</sub><sup>-1</sup> cm<sup>-2</sup>, with a detection limit of <InlineParagraph>0.09 μGy<sub>air</sub>·s<sup>-1</sup></InlineParagraph> (under different voltages and dose rates). In self-powered mode, its sensitivity reaches <InlineParagraph>110.72 μC·Gy<sub>air</sub><sup>-1</sup> cm<sup>-2</sup>,</InlineParagraph> with a detection limit of 0.061 μGy<sub>air</sub>·s<sup>-1,</sup> outperforming conventional materials such as α-Se. This self-powered capability stems from a highly efficient charge separation mechanism driven by a built-in electric field, thereby reducing power consumption and system complexity and enabling portable detection. Owing to the structural anisotropy, which leads to anisotropic carrier transport and dark current, the sensitivity peaks along the Y-axis, while the detection limit is lowest along the X-axis. This correlation between structure and performance provides an important design principle for oxide-based X-ray detectors that balances sensitivity and detection limits. It is anticipated that further optimization of crystal growth processes, electrode design, and interface engineering will enhance overall detection and imaging performance. These results confirm that KTA is a highly promising material for portable low-dose X-ray detection and provide an experimental foundation for its future practical application.</p>
    </sec>
  </body>
  <back>
    <sec>
      <title>DECLARATIONS</title>
      <sec>
        <title>Acknowledgement</title>
        <p>The authors gratefully acknowledge Guo Feifei for her assistance with experimental instrument usage and data processing methods. We thank Sun Youxuan and Zhai Zhongjun for generously providing the KTA crystals.</p>
      </sec>
      <sec>
        <title>Authors' contributions</title>
		<p>Investigation, data curation, formal analysis, visualization, writing - original draft: Hu, Y.</p>
        <p>Conceptualization, supervision, funding acquisition, review &amp; editing: Sun, W.</p>
        <p>Methodology, resources, validation: Feng, X.</p>
        <p>Investigation, formal analysis: Hu, F.</p>
        <p>Conceptualization, supervision, project administration, funding acquisition, review &amp; editing: Gao, Z.</p>
      </sec>
      <sec>
        <title>Availability of data and materials</title>
        <p>The data supporting the findings of this study are available within this Article and its <inline-supplementary-material content-type="local-data" mimetype="application/pdf" xlink:href="microstructures60142-SupplementaryMaterials.pdf">Supplementary Materials</inline-supplementary-material>. Further data are available from the corresponding authors upon reasonable request.</p>
      </sec>
      <sec>
        <title>AI and AI-assisted tools statement</title>
        <p>During the preparation of this work, the authors used (DeepL, version 25.8.2.17787, 2025-09-01) for language polishing and grammar checking. After using these tools, the authors reviewed and edited the content as needed. The authors take full responsibility for the final content of publication.</p>
      </sec>
      <sec>
        <title>Financial support and sponsorship</title>
        <p>This work was financially supported by the National Natural Science Foundation of China (grant no. 62175129), the Natural Science Foundation of Shandong Province (No. ZR2025ZD31).</p>
      </sec>
      <sec>
        <title>Conflict of interest</title>
        <p>All authors declared that there are no conflicts of interest.</p>
      </sec>
      <sec>
        <title>Ethical approval and consent to participate</title>
        <p>Not applicable.</p>
      </sec>
      <sec>
        <title>Consent for publication</title>
        <p>Not applicable.</p>
      </sec>
      <sec>
        <title>Copyright</title>
        <p>© The Author(s) 2026.</p>
      </sec>
	 <sec sec-type="supplementary-material">
        <title>Supplementary Materials</title>
        <supplementary-material content-type="local-data">
          <media xlink:href="microstructures60142-SupplementaryMaterials.pdf" mimetype="application/pdf">
            <caption>
              <p>Supplementary Materials</p>
            </caption>
          </media>
        </supplementary-material>
      </sec> 
    </sec>
    <ref-list>
      <ref id="B1">
        <label>1</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Jana</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Cho</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Patil</surname>
              <given-names>SA</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Perovskite: scintillators, direct detectors, and X-ray imagers</article-title>
          <source>Mater Today</source>
          <year>2022</year>
          <volume>55</volume>
          <fpage>110</fpage>
          <lpage>36</lpage>
          <pub-id pub-id-type="doi">10.1016/j.mattod.2022.04.009</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B2">
        <label>2</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Aamir</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Shahiduzzaman</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Taima</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Akhtar</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Nunzi</surname>
              <given-names>JM</given-names>
            </name>
          </person-group>
          <article-title>It is an all-rounder! On the development of metal halide perovskite-based fluorescent sensors and radiation detectors</article-title>
          <source>Adv Opt Mater</source>
          <year>2021</year>
          <volume>9</volume>
          <fpage>2101276</fpage>
          <pub-id pub-id-type="doi">10.1002/adom.202101276</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B3">
        <label>3</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chen</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Li</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Zhao</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Ming</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Xue</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
          <article-title>Nanocrystals of metal halide perovskites and their analogues as scintillators for x-ray detection</article-title>
          <source>Nano Futures</source>
          <year>2022</year>
          <volume>6</volume>
          <fpage>012001</fpage>
          <pub-id pub-id-type="doi">10.1088/2399-1984/ac421c</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B4">
        <label>4</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Cho</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Kang</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Kwon</surname>
              <given-names>C</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Effect of annealing on the X-ray detection properties of nano-sized polycrystalline lead oxide films</article-title>
          <source>Jpn J Appl Phys</source>
          <year>2008</year>
          <volume>47</volume>
          <fpage>7393</fpage>
          <pub-id pub-id-type="doi">10.1143/jjap.47.7393</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B5">
        <label>5</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zhou</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Li</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Lan</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>Q</given-names>
            </name>
            <name>
              <surname>Ding</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Jin</surname>
              <given-names>Z</given-names>
            </name>
          </person-group>
          <article-title>Halide perovskite, a potential scintillator for X-ray detection</article-title>
          <source>Small Methods</source>
          <year>2020</year>
          <volume>4</volume>
          <fpage>2000506</fpage>
          <pub-id pub-id-type="doi">10.1002/smtd.202000506</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B6">
        <label>6</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pauwels</surname>
              <given-names>K</given-names>
            </name>
            <name>
              <surname>Douissard</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
          <article-title>Indirect X-ray detectors with single-photon sensitivity</article-title>
          <source>J Synchrotron Rad</source>
          <year>2022</year>
          <volume>29</volume>
          <fpage>1394</fpage>
          <lpage>406</lpage>
          <pub-id pub-id-type="doi">10.1107/s1600577522009584</pub-id>
          <pub-id pub-id-type="pmid">36345747</pub-id>
          <pub-id pub-id-type="pmcid">PMC9641558</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B7">
        <label>7</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Geng</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Chen</surname>
              <given-names>YA</given-names>
            </name>
            <name>
              <surname>Li</surname>
              <given-names>YY</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Lead-free halide perovskites for direct X-ray detectors</article-title>
          <source>Adv Sci</source>
          <year>2023</year>
          <volume>10</volume>
          <fpage>2300256</fpage>
          <pub-id pub-id-type="doi">10.1002/advs.202300256</pub-id>
          <pub-id pub-id-type="pmid">37232232</pub-id>
          <pub-id pub-id-type="pmcid">PMC10427383</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B8">
        <label>8</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wu</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Ge</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Niu</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Tang</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Metal halide perovskites for X-ray detection and imaging</article-title>
          <source>Matter</source>
          <year>2021</year>
          <volume>4</volume>
          <fpage>144</fpage>
          <lpage>63</lpage>
          <pub-id pub-id-type="doi">10.1016/j.matt.2020.11.015</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B9">
        <label>9</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wronski</surname>
              <given-names>MM</given-names>
            </name>
            <name>
              <surname>Rowlands</surname>
              <given-names>JA</given-names>
            </name>
          </person-group>
          <article-title>Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI</article-title>
          <source>Med Phys</source>
          <year>2008</year>
          <volume>35</volume>
          <fpage>5207</fpage>
          <lpage>18</lpage>
          <pub-id pub-id-type="doi">10.1118/1.3002314</pub-id>
          <pub-id pub-id-type="pmid">19175080</pub-id>
          <pub-id pub-id-type="pmcid">PMC2673615</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B10">
        <label>10</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kasap</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Frey</surname>
              <given-names>JB</given-names>
            </name>
            <name>
              <surname>Belev</surname>
              <given-names>G</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Amorphous and polycrystalline photoconductors for direct conversion flat panel X-ray image sensors</article-title>
          <source>Sensors</source>
          <year>2011</year>
          <volume>11</volume>
          <fpage>5112</fpage>
          <lpage>57</lpage>
          <pub-id pub-id-type="doi">10.3390/s110505112</pub-id>
          <pub-id pub-id-type="pmid">22163893</pub-id>
          <pub-id pub-id-type="pmcid">PMC3231396</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B11">
        <label>11</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Basiricò</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Ciavatti</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Fraboni</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Solution-grown organic and perovskite X-ray detectors: a new paradigm for the direct detection of ionizing radiation</article-title>
          <source>Adv Mater Technol</source>
          <year>2020</year>
          <volume>6</volume>
          <fpage>2000475</fpage>
          <pub-id pub-id-type="doi">10.1002/admt.202000475</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B12">
        <label>12</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chaudhari</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Ravikant</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>A review on BiI3 perovskites and composites for direct X-ray detection</article-title>
          <source>Sens Actuator Phys</source>
          <year>2022</year>
          <volume>346</volume>
          <fpage>113863</fpage>
          <pub-id pub-id-type="doi">10.1016/j.sna.2022.113863</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B13">
        <label>13</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sun</surname>
              <given-names>XJ</given-names>
            </name>
            <name>
              <surname>Xia</surname>
              <given-names>ML</given-names>
            </name>
            <name>
              <surname>Xu</surname>
              <given-names>YS</given-names>
            </name>
            <name>
              <surname>Tang</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Niu</surname>
              <given-names>GD</given-names>
            </name>
          </person-group>
          <article-title>Research progress of perovskite direct X-ray imaging</article-title>
          <source>Chin J Lumin</source>
          <year>2022</year>
          <volume>43</volume>
          <fpage>1014</fpage>
          <lpage>26</lpage>
          <pub-id pub-id-type="doi">10.37188/cjl.20220119</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B14">
        <label>14</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Li</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Adeagbo</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Koughia</surname>
              <given-names>C</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Direct conversion X-ray detectors with 70 pA cm<sup>-2</sup> dark currents coated from an alcohol-based perovskite ink</article-title>
          <source>J Mater Chem C</source>
          <year>2022</year>
          <volume>10</volume>
          <fpage>1228</fpage>
          <lpage>35</lpage>
          <pub-id pub-id-type="doi">10.1039/d1tc05338h</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B15">
        <label>15</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Anagnost</surname>
              <given-names>KM</given-names>
            </name>
            <name>
              <surname>Lee</surname>
              <given-names>E</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Liu</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Fossum</surname>
              <given-names>ER</given-names>
            </name>
          </person-group>
          <article-title>Simulating 50 keV X-ray photon detection in silicon with a down-conversion layer</article-title>
          <source>Sensors</source>
          <year>2021</year>
          <volume>21</volume>
          <fpage>7566</fpage>
          <pub-id pub-id-type="doi">10.3390/s21227566</pub-id>
          <pub-id pub-id-type="pmid">34833642</pub-id>
          <pub-id pub-id-type="pmcid">PMC8618102</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B16">
        <label>16</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Eisen</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Shor</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Mardor</surname>
              <given-names>I</given-names>
            </name>
          </person-group>
          <article-title>CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems</article-title>
          <source>IEEE Trans Nucl Sci</source>
          <year>2004</year>
          <volume>51</volume>
          <fpage>1191</fpage>
          <lpage>8</lpage>
          <pub-id pub-id-type="doi">10.1109/tns.2004.829437</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B17">
        <label>17</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sellin</surname>
              <given-names>PJ</given-names>
            </name>
            <name>
              <surname>Prekas</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Franc</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Grill</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Electric field distributions in CdZnTe due to reduced temperature and X-ray irradiation</article-title>
          <source>Appl Phys Lett</source>
          <year>2010</year>
          <volume>96</volume>
          <fpage>133509</fpage>
          <pub-id pub-id-type="doi">10.1063/1.3373526</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B18">
        <label>18</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zhu</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Du</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Niu</surname>
              <given-names>G</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Template directed perovskite X-ray detectors towards low ionic migration and low interpixel cross talking</article-title>
          <source>Fundam Res</source>
          <year>2022</year>
          <volume>2</volume>
          <fpage>108</fpage>
          <lpage>13</lpage>
          <pub-id pub-id-type="doi">10.1016/j.fmre.2021.10.004</pub-id>
          <pub-id pub-id-type="pmid">38933912</pub-id>
          <pub-id pub-id-type="pmcid">PMC11197728</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B19">
        <label>19</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Huang</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Qiao</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Jiang</surname>
              <given-names>Y</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>A-site cation engineering for highly efficient MAPbI<sub>3</sub> single-crystal X-ray detector</article-title>
          <source>Angew Chem Int Ed</source>
          <year>2019</year>
          <volume>58</volume>
          <fpage>17834</fpage>
          <lpage>42</lpage>
          <pub-id pub-id-type="doi">10.1002/anie.201911281</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B20">
        <label>20</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Fan</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Chen</surname>
              <given-names>Q</given-names>
            </name>
            <name>
              <surname>Li</surname>
              <given-names>Z</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Realization of passive X-ray detection with a low detection limit in dion-jacobson halide hybrid perovskite</article-title>
          <source>Small</source>
          <year>2023</year>
          <volume>19</volume>
          <fpage>2303814</fpage>
          <pub-id pub-id-type="doi">10.1002/smll.202303814</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B21">
        <label>21</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pan</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Liu</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Welton</surname>
              <given-names>C</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Ultrahigh-flux X-ray detection by a solution-grown perovskite CsPbBr<sub>3</sub> single-crystal semiconductor detector</article-title>
          <source>Adv Mater</source>
          <year>2023</year>
          <volume>35</volume>
          <fpage>2211840</fpage>
          <pub-id pub-id-type="doi">10.1002/adma.202211840</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B22">
        <label>22</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pisoni</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Jaćimović</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Barišić</surname>
              <given-names>OS</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Ultra-low thermal conductivity in organic-inorganic hybrid perovskite CH<sub>3</sub>NH<sub>3</sub>PbI<sub>3</sub></article-title>
          <source>J Phys Chem Lett</source>
          <year>2014</year>
          <volume>5</volume>
          <fpage>2488</fpage>
          <lpage>92</lpage>
          <pub-id pub-id-type="doi">10.1021/jz5012109</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B23">
        <label>23</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lee</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Li</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Wong</surname>
              <given-names>AB</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Ultralow thermal conductivity in all-inorganic halide perovskites</article-title>
          <source>Proc Natl Acad Sci USA</source>
          <year>2017</year>
          <volume>114</volume>
          <fpage>8693</fpage>
          <lpage>7</lpage>
          <pub-id pub-id-type="doi">10.1073/pnas.1711744114</pub-id>
          <pub-id pub-id-type="pmid">28760988</pub-id>
          <pub-id pub-id-type="pmcid">PMC5565476</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B24">
        <label>24</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Heiderhoff</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Haeger</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Pourdavoud</surname>
              <given-names>N</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Thermal conductivity of methylammonium lead halide perovskite single crystals and thin films: a comparative study</article-title>
          <source>J Phys Chem C</source>
          <year>2017</year>
          <volume>121</volume>
          <fpage>28306</fpage>
          <lpage>11</lpage>
          <pub-id pub-id-type="doi">10.1021/acs.jpcc.7b11495</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B25">
        <label>25</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Guo</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Hu</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Song</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Gao</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Tao</surname>
              <given-names>X</given-names>
            </name>
          </person-group>
          <article-title>High-performance oxide crystal BaTeW<sub>2</sub>O<sub>9</sub> X-ray detector with high stability, low detection limit, and ultralow dark current drift</article-title>
          <source>ACS Appl Mater Interfaces</source>
          <year>2025</year>
          <volume>17</volume>
          <fpage>9530</fpage>
          <lpage>8</lpage>
          <pub-id pub-id-type="doi">10.1021/acsami.4c17909</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B26">
        <label>26</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Hu</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Guo</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Mu</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Cao</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Gao</surname>
              <given-names>Z</given-names>
            </name>
          </person-group>
          <article-title>Effect of internal electrostatic fields on self-powered X-ray detectors with high sensitivity and low detection limits in polar oxide crystals α/<italic>β</italic>-BaTeMo<sub>2</sub>O<sub>9</sub></article-title>
          <source>Small</source>
          <year>2025</year>
          <volume>21</volume>
          <fpage>2502928</fpage>
          <pub-id pub-id-type="doi">10.1002/smll.202502928</pub-id>
          <pub-id pub-id-type="pmid">40249214</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B27">
        <label>27</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Jin</surname>
              <given-names>P</given-names>
            </name>
            <name>
              <surname>Tang</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Xu</surname>
              <given-names>X</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Solution-processed perovskite/metal-oxide hybrid X-ray detector and array with decoupled electronic and ionic transport pathways</article-title>
          <source>Small Methods</source>
          <year>2022</year>
          <volume>6</volume>
          <fpage>2200500</fpage>
          <pub-id pub-id-type="doi">10.1002/smtd.202200500</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B28">
        <label>28</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lujan</surname>
              <given-names>RA</given-names>
            </name>
            <name>
              <surname>Street</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
          <article-title>Flexible X-ray detector array fabricated with oxide thin-film transistors</article-title>
          <source>IEEE Electron Device Lett</source>
          <year>2012</year>
          <volume>33</volume>
          <fpage>688</fpage>
          <lpage>90</lpage>
          <pub-id pub-id-type="doi">10.1109/led.2012.2188825</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B29">
        <label>29</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wei</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Huang</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Halide lead perovskites for ionizing radiation detection</article-title>
          <source>Nat Commun</source>
          <year>2019</year>
          <volume>10</volume>
          <fpage>1066</fpage>
          <pub-id pub-id-type="doi">10.1038/s41467-019-08981-w</pub-id>
          <pub-id pub-id-type="pmid">30842411</pub-id>
          <pub-id pub-id-type="pmcid">PMC6403296</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B30">
        <label>30</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wei</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Fang</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Mulligan</surname>
              <given-names>P</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals</article-title>
          <source>Nat Photonics</source>
          <year>2016</year>
          <volume>10</volume>
          <fpage>333</fpage>
          <lpage>9</lpage>
          <pub-id pub-id-type="doi">10.1038/nphoton.2016.41</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B31">
        <label>31</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zhuang</surname>
              <given-names>R</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Ma</surname>
              <given-names>W</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Highly sensitive X-ray detector made of layered perovskite-like (NH<sub>4</sub>)<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single crystal with anisotropic response</article-title>
          <source>Nat Photonics</source>
          <year>2019</year>
          <volume>13</volume>
          <fpage>602</fpage>
          <lpage>8</lpage>
          <pub-id pub-id-type="doi">10.1038/s41566-019-0466-7</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B32">
        <label>32</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kasap</surname>
              <given-names>SO</given-names>
            </name>
            <name>
              <surname>Rowlands</surname>
              <given-names>JA</given-names>
            </name>
          </person-group>
          <article-title>Review X-ray photoconductors and stabilized a-Se for direct conversion digital flat-panel X-ray image-detectors</article-title>
          <source>J Mater Sci Mater Electron</source>
          <year>2000</year>
          <volume>11</volume>
          <fpage>179</fpage>
          <lpage>98</lpage>
          <pub-id pub-id-type="doi">10.1023/a:1008993813689</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B33">
        <label>33</label>
        <nlm-citation publication-type="book">
          <person-group person-group-type="author">
            <name>
              <surname>Berger</surname>
              <given-names>MJ</given-names>
            </name>
            <name>
              <surname>Hubbell</surname>
              <given-names>JH</given-names>
            </name>
            <name>
              <surname>Seltzer</surname>
              <given-names>SM</given-names>
            </name>
            <etal />
          </person-group>
          <comment>XCOM: photon cross sections database: NIST standard reference database 8 (XGAM). 2010.</comment>
          <pub-id pub-id-type="doi">10.18434/T48G6X</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B34">
        <label>34</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chen</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Tang</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Liu</surname>
              <given-names>B</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>High-performance X-ray detector based on single-crystal β-Ga<sub>2</sub>O<sub>3</sub>:Mg</article-title>
          <source>ACS Appl Mater Interfaces</source>
          <year>2021</year>
          <volume>13</volume>
          <fpage>2879</fpage>
          <lpage>86</lpage>
          <pub-id pub-id-type="doi">10.1021/acsami.0c20574</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B35">
        <label>35</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Li</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Chen</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Tang</surname>
              <given-names>H</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Band gap engineering in β-Ga<sub>2</sub>O<sub>3</sub> for a high-performance X-ray detector</article-title>
          <source>ACS Appl Electron Mater</source>
          <year>2021</year>
          <volume>3</volume>
          <fpage>4630</fpage>
          <lpage>9</lpage>
          <pub-id pub-id-type="doi">10.1021/acsaelm.1c00778</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B36">
        <label>36</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Li</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Chang</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Zhang</surname>
              <given-names>H</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Cu-based metal-organic frameworks for highly sensitive X-ray detectors</article-title>
          <source>Chem Commun</source>
          <year>2021</year>
          <volume>57</volume>
          <fpage>8612</fpage>
          <lpage>5</lpage>
          <pub-id pub-id-type="doi">10.1039/d1cc03458h</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B37">
        <label>37</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Ge</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Chen</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Fu</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Feng</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Wang</surname>
              <given-names>D</given-names>
            </name>
            <name>
              <surname>Yuan</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Effects of fluorinated aromatic spacer in Ag-Bi double perovskite for X-ray detector</article-title>
          <source>J Phys Chem</source>
          <year>2022</year>
          <volume>126</volume>
          <fpage>19417</fpage>
          <lpage>23</lpage>
          <pub-id pub-id-type="doi">10.1021/acs.jpcc.2c05442</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B38">
        <label>38</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pan</surname>
              <given-names>W</given-names>
            </name>
            <name>
              <surname>Wu</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Luo</surname>
              <given-names>J</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Cs<sub>2</sub>AgBiBr<sub>6</sub> single-crystal X-ray detectors with a low detection limit</article-title>
          <source>Nat Photonics</source>
          <year>2017</year>
          <volume>11</volume>
          <fpage>726</fpage>
          <lpage>32</lpage>
          <pub-id pub-id-type="doi">10.1038/s41566-017-0012-4</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B39">
        <label>39</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zhang</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Liu</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Xu</surname>
              <given-names>Z</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Nucleation-controlled growth of superior lead-free perovskite Cs<sub>3</sub>Bi<sub>2</sub>I<sub>9</sub> single-crystals for high-performance X-ray detection</article-title>
          <source>Nat Commun</source>
          <year>2020</year>
          <volume>11</volume>
          <fpage>2304</fpage>
          <pub-id pub-id-type="doi">10.1038/s41467-020-16034-w</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B40">
        <label>40</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Guo</surname>
              <given-names>J</given-names>
            </name>
            <name>
              <surname>Xu</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Yang</surname>
              <given-names>W</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>High-stability flexible X-ray detectors based on lead-free halide perovskite Cs<sub>2</sub>TeI<sub>6</sub> films</article-title>
          <source>ACS Appl Mater Interfaces</source>
          <year>2021</year>
          <volume>13</volume>
          <fpage>23928</fpage>
          <lpage>35</lpage>
          <pub-id pub-id-type="doi">10.1021/acsami.1c04252</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B41">
        <label>41</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Wei</surname>
              <given-names>Q</given-names>
            </name>
            <name>
              <surname>Fan</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Xiang</surname>
              <given-names>P</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Cs<sub>3</sub>Cu<sub>2</sub>I<sub>5</sub> single crystal for efficient direct X-ray detection</article-title>
          <source>Adv Opt Mater</source>
          <year>2023</year>
          <volume>11</volume>
          <fpage>2300247</fpage>
          <pub-id pub-id-type="doi">10.1002/adom.202300247</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B42">
        <label>42</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Ma</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Chen</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Song</surname>
              <given-names>X</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Centimeter-sized molecular perovskite crystal for efficient X-ray detection</article-title>
          <source>Adv Funct Mater</source>
          <year>2021</year>
          <volume>31</volume>
          <fpage>2100691</fpage>
          <pub-id pub-id-type="doi">10.1002/adfm.202100691</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B43">
        <label>43</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zhou</surname>
              <given-names>L</given-names>
            </name>
            <name>
              <surname>Lu</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Wu</surname>
              <given-names>J</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Self-powered fast-response X-ray detectors based on vertical GaN p-n diodes</article-title>
          <source>IEEE Electron Device Lett</source>
          <year>2019</year>
          <volume>40</volume>
          <fpage>1044</fpage>
          <lpage>7</lpage>
          <pub-id pub-id-type="doi">10.1109/led.2019.2914585</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B44">
        <label>44</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Xu</surname>
              <given-names>Q</given-names>
            </name>
            <name>
              <surname>Zhang</surname>
              <given-names>B</given-names>
            </name>
            <name>
              <surname>Nie</surname>
              <given-names>J</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Self-powered X-ray detector based on methylammonium lead tribromide single crystals</article-title>
          <source>J Alloys Compd</source>
          <year>2021</year>
          <volume>859</volume>
          <fpage>157826</fpage>
          <pub-id pub-id-type="doi">10.1016/j.jallcom.2020.157826</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B45">
        <label>45</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Guan</surname>
              <given-names>Q</given-names>
            </name>
            <name>
              <surname>You</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Zhu</surname>
              <given-names>ZK</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Three-dimensional polar perovskites for highly sensitive self-driven X-ray detection</article-title>
          <source>Angew Chem Int Ed</source>
          <year>2024</year>
          <volume>63</volume>
          <fpage>e202320180</fpage>
          <pub-id pub-id-type="doi">10.1002/anie.202320180</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B46">
        <label>46</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Gou</surname>
              <given-names>Z</given-names>
            </name>
            <name>
              <surname>Huanglong</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Ke</surname>
              <given-names>W</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Self-powered X-ray detector based on all-inorganic perovskite thick film with high sensitivity under low dose rate</article-title>
          <source>Phys Status Solid RRL</source>
          <year>2019</year>
          <volume>13</volume>
          <fpage>1900094</fpage>
          <pub-id pub-id-type="doi">10.1002/pssr.201900094</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B47">
        <label>47</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Tsai</surname>
              <given-names>H</given-names>
            </name>
            <name>
              <surname>Liu</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Shrestha</surname>
              <given-names>S</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>A sensitive and robust thin-film X-ray detector using 2D layered perovskite diodes</article-title>
          <source>Sci Adv</source>
          <year>2020</year>
          <volume>6</volume>
          <fpage>eaay0815</fpage>
          <pub-id pub-id-type="doi">10.1126/sciadv.aay0815</pub-id>
          <pub-id pub-id-type="pmid">32300647</pub-id>
          <pub-id pub-id-type="pmcid">PMC7148088</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B48">
        <label>48</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Zhang</surname>
              <given-names>X</given-names>
            </name>
            <name>
              <surname>Zhu</surname>
              <given-names>T</given-names>
            </name>
            <name>
              <surname>Ji</surname>
              <given-names>C</given-names>
            </name>
            <name>
              <surname>Yao</surname>
              <given-names>Y</given-names>
            </name>
            <name>
              <surname>Luo</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>
            <italic>In situ</italic> epitaxial growth of centimeter-sized lead-free (BA)<sub>2</sub>CsAgBiBr<sub>7</sub>/Cs<sub>2</sub>AgBiBr<sub>6</sub> heterocrystals for self-driven X-ray detection</article-title>
          <source>J Am Chem Soc</source>
          <year>2021</year>
          <volume>143</volume>
          <fpage>20802</fpage>
          <lpage>10</lpage>
          <pub-id pub-id-type="doi">10.1021/jacs.1c08959</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B49">
        <label>49</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Girolami</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Matteocci</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Pettinato</surname>
              <given-names>S</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Metal-halide perovskite submicrometer-thick films for ultra-stable self-powered direct X-ray detectors</article-title>
          <source>Nano Micro Lett</source>
          <year>2024</year>
          <volume>16</volume>
          <fpage>182</fpage>
          <pub-id pub-id-type="doi">10.1007/s40820-024-01393-6</pub-id>
          <pub-id pub-id-type="pmid">38668830</pub-id>
          <pub-id pub-id-type="pmcid">PMC11052987</pub-id>
        </nlm-citation>
      </ref>
      <ref id="B50">
        <label>50</label>
        <nlm-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Rosenman</surname>
              <given-names>G</given-names>
            </name>
            <name>
              <surname>Skliar</surname>
              <given-names>A</given-names>
            </name>
            <name>
              <surname>Findling</surname>
              <given-names>Y</given-names>
            </name>
            <etal />
          </person-group>
          <article-title>Periodically poled KTiOAsO<sub>4</sub> crystals for optical parametric oscillation</article-title>
          <source>J Phys D Appl Phys</source>
          <year>1999</year>
          <volume>32</volume>
          <fpage>L49</fpage>
          <lpage>52</lpage>
          <pub-id pub-id-type="doi">10.1088/0022-3727/32/14/101</pub-id>
        </nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>